START-UP PROCEDURE

Your ECO pump (variable speed pump) is designed for maximum energy efficiency whilst still
keeping your pool crystal clear.  To maximise the energy efficiency, the ECO pump should be
run at the lowest speed setting possible to efficiently filter your pool water.  It is recommended
that the first speed setting

(Green Button)

should be set to this filtration speed and used for at

least 6-8 hours per day, whilst the second speed setting

(Pink Button)

is set for use only with

automatic suction cleaners and used once a week only.  The third speed setting

(Blue Button)

should be set to maximum speed and only used for backwashing and manual vacuuming.

Once the pump has been plumbed in and the glue has cured, it is time to prime the pump.

Follow the instructions below:

1.

Check all the connections are hand tight

2.

Remove the lid from the pump by turning the lock ring anti-clockwise - put these aside for
later use

3.

Fill the hair and lint pot with water to the bottom of the inlet (around 4 litres)

4.

Refit the lid and lock ring ensuring the O-ring is in place

5.

Open any inline valves. Make sure the filter multiport valve is not in the closed position.

6.

Switch on the power at the power supply and the ECO pump will automatically run the
“priming” mode (full speed) for 3 minutes. The pump should automatically prime within
this period but if it doesn’t please follow steps 1 through to step 6 again. Once the pump
has primed, select the first speed setting

(green)

and adjust the speed for best filtration

flow ensuring the salt chlorinator cell (if fitted) has filled with water.

NOTE: If pump has not primed after the second attempt, please contact your pool

professional to prevent damage to the mechanical seal occurring from insufficient
water flow.

Summary of Contents for ECO:100

Page 1: ...INSTALLATION OPERATION ECO 100 ECO 150...

Page 2: ...The Noria ECO difference continues with the use of stainless steel shafts for strength larger hair and lint pots reduce the need for frequent cleaning The research invested in Noria ECO pumps is refle...

Page 3: ...suring the O rings are attached 40mm and 50mm are supplied depending on the size of pipe 4 Plumb the suction side of the pump to the skimmer suction pipe including any valves required 5 Plumb the disc...

Page 4: ...1 Check all the connections are hand tight 2 Remove the lid from the pump by turning the lock ring anti clockwise put these aside for later use 3 Fill the hair and lint pot with water to the bottom o...

Page 5: ...isplay an error code note the error code and consult your local agent Adjustable Speed Mode this feature is available following the 5 minute priming period Press Button Press and Hold or for approxima...

Page 6: ...around the pump is wet or damp it indicates there is a leak Trace the leak to the source and repair the problem 1 Check to make sure all the barrel unions are tight and O rings are fitted 2 If the pum...

Page 7: ...is used DO NOT use petroleum based products as these result in damage to the O rings The mechanical seal consists of two parts A spring loaded rotating seal with a polished carbon face and a stationar...

Page 8: ...inimum operating head in metres for this appliance is 2m The maximum total head in metres for this appliance is between 2 12m The pump is to be either supplied by an isolating transformer or supplied...

Reviews: