6.1 Electrical connection
!
DANGER
Danger of injury caused by improper
connection!
Danger of death through contact with
live components. When switched on,
electrical components can perform
uncontrolled movements and result in
serious injury or death.
´
Isolate the electrical supply before
starting work and make sure it cannot
be switched back on.
1. Make sure that connectors for the
electrical connection are available. If
necessary, obtain them from the manu-
facturer - see section
1.6
Manufacturer‘s
address
.
2. Connect the safety valves in accordance
with the specifications on the type plate.
!
ADVICE
If using a two-hand control,
ensure that the actuating solenoids are
actuated by an output signal from an
electrical two-hand control of type III C per
DIN EN 574.
Valve connection
1 (P) Compressed air connection
2 (A) Working connection
3 (R) Venting connection via silencer
2 (A)
1 (P)
3 (R)
3 (R)
7503618000000006