*TA / TK FURNACES with VARIABLE SPEED BLOWERS
“A” CABINET
Switch Settings For Heat
(0 = OFF, 1 = ON)
*TA / TK - 060C - VA1
Input (BTU) 60,000
1
2
3
4
CFM
Temp Rise (° F)
0
0
0
0
640
69
0
0
0
1
720
62
0
0
1
0
800
56
0
0
1
1
880
51
0
1
0
0
960
46
0
1
0
1
1,040
43
0
1
1
0
1,120
40
0
1
1
1
1,200
37
“B” CABINET
Switch Settings For Heat
(0 = OFF, 1 = ON)
*TA / TK - 080C - VB1
Input (BTU) 80,000
*TA - 100C - VB1
Input (BTU) 100,000
1
2
3
4
CFM
Temp Rise (°F)
CFM
Temp Rise (° F)
1
0
0
0
1,000
59
1,000
74
1
0
0
1
1,100
54
1,100
67
1
0
1
0
1,200
49
1,200
62
1
0
1
1
1,300
46
1,300
57
1
1
0
0
1,400
42
1,400
53
1
1
0
1
1,500
40
1,500
49
1
1
1
0
1,600
37
1,600
46
1
1
1
1
1,700
35
1,700
44
“C” CABINET
Switch Settings For Heat
(0 = OFF, 1 = ON)
*TA / TK - 100C - VC1
Input (BTU) 100,000
*TA / TK - 120C - VC1
Input (BTU) 120,000
1
2
3
4
CFM
Temp Rise (° F)
CFM
Temp Rise (° F)
#
0
0
0
1,000
74
1,000
89
#
0
0
1
1,115
66
1,115
80
#
0
1
0
1,230
60
1,230
72
#
0
1
1
1,345
55
1,345
66
#
1
0
0
1,460
51
1,460
61
#
1
0
1
1,575
47
1,575
56
#
1
1
0
1,690
44
1,690
53
#
1
1
1
1,805
41
1,805
49
“D” CABINET
Switch Settings For Heat
(0 = OFF, 1 = ON)
*TA / TK - 140C - VD1
Input (BTU) 140,000
1
2
3
4
CFM
Temp Rise (° F)
#
0
0
0
1,500
69
#
0
0
1
1,615
64
#
0
1
0
1,730
60
#
0
1
1
1,845
56
#
1
0
0
1,960
53
#
1
0
1
2,075
50
#
1
1
0
2,190
47
#
1
1
1
2,305
45
NOTES:
# Switch not used - can be 0 or 1
1. Two openings are recommended for airfl ows above 1,600 CFM if the fi lter(s) is (are) adjacent to the furnace.
2. Temperature rises in the table are approximate. Actual temperature rises may vary.
3. Temperature rises shaded in grey are for reference only. These conditions are not recommended.
Table 6. Nominal Heating Airfl ows (CFM) & Temperature Rise (° F)