background image

 

8  

 

 

To turn off an active zone, first make a brief touch anywhere in the screen.  After a momentary 
delay, one of the User Setup screens shown above will be displayed for 4 seconds, during 
which time a touch to the ON/OFF icon will deactivate the zone. When the zone is deactivated, 
it will show the Zone OFF screen (Figure4A). 
 

4.4 The User Setup Screen 

 

For the user to make a change in his/her preferences for a particular zone, it is necessary to 
enter the User Setup Screen in that zone’s local thermostat.  With the zone activated as 
described in the previous section, from the Normal Screen (Figure 3) make a brief touch 
anywhere on the screen.  For component combinations that support it, the backlight will 
illuminate immediately.  After a momentary delay, the User Setup Screen (Figure 5A or 5B) will 
be displayed for approximately 4 seconds.  From this screen the zone can be turned off or on as 
described above.  At this time the setpoint for the current mode of operation can be adjusted as 
described in the following sections.  If the iQ controller is in any mode other than OFF, the icon 
for heating or cooling will flash briefly to indicate which of these is the active mode. 

If the Airzone icon is touched while the User Setup screen is displayed, a Mode Selection 
screen will appear, which permits selection of other options, including manual versus 
auto/program control, ventilation, sleep mode, and program scheduling.  Details for these 
options are discussed elsewhere in  this manual. 

If the zone is not activated (turned on), no User Setup screen will appear.  In that case a single 
touch to the Airzone icon will allow mode selection as described above. 
If the center of the User Setup screen is touched and held for a couple of seconds, the local 
zone number will be identified.  After a few seconds the display will return to the Normal Screen.  
See also Accessing Another Zone From Any Thermostat, later in this manual. 
 

Temperature Setpoint– General 

The iQ Zone system supports dual temperature setpoints which apply separately to heating and 
cooling.If AUTO (autochangeover) mode is selected at the iQ Controller, the selection between 
starting in heating and cooling is made based on whichever demand is greater at the time. 

If a zone thermostat is turned off (deactivated), it remembers the setpoint (either manual or 
automatic) and re-applies it when that zone is turned back on.Setpoint adjustment may be  
 

.

09

:

13 

 

Figure 5C. 

User Setup Screen (from Off) 

Summary of Contents for Airzone iQ Zone

Page 1: ...User s Manual...

Page 2: ......

Page 3: ...1 Setpoint Changes within a Day 12 4 8 2 Setpoint Changes within a Week 13 4 8 3 Planning 15 4 9 Automatic Setpoint Control Procedure for entering a Schedule 15 4 10 Automatic Setpoint Control Viewing...

Page 4: ...Do not ever dispose of this equipment with household waste Electrical and electronic products contain substances that can be harmful to the environment if they are not given proper treatment The symbo...

Page 5: ...t of each room For instance a room that is situated in a shaded area requires less cooling power in order to lower the room s temperature while rooms exposed to full sunlight usually require less powe...

Page 6: ...iQ Controller This includes HEAT COOL E HEAT for heat pumps AUTO autochangeover between heating and cooling FAN ON system wide ventilation and zone control enabled or disabled Other options are availa...

Page 7: ...eOFFFigure Figure 4B Zone ON Figure 4C Zone ON To activate a zone that is off Figure 4A and return to the previously used operating mode Manual or Auto Setpoint Control touch the ON OFF icon briefly A...

Page 8: ...ly to indicate which of these is the active mode If the Airzone icon is touched while the User Setup screen is displayed a Mode Selection screen will appear which permits selection of other options in...

Page 9: ...n the screen then b touching the ON OFF icon With the zone off touch the Airzone icon once This will display a hand icon and an A in a box above the blinking ON OFF icon as in Figure 6A below Touch th...

Page 10: ...All days 1 7 every day For any of the above up to three time blocks called programs may be defined by making entries at the zone thermostat Each of these time blocks is associated with a pair of tempe...

Page 11: ...Switching to Automatic Setpoint Control In order to run the zoning system utilizing program scheduled temperature setpoints the control must be a in the Automatic Setpoint control mode and b turned on...

Page 12: ...them In the explanation below each setpoint really refers to a single pair of setpoints one for cooling and one for heating If you are only interested in setting one of these for the schedule you may...

Page 13: ...in which the two typical setback times night time and midday have the same setpoint 74 and the most active times morning and evening use different setpoints 72 from PROG 2 in the morning and 71 from...

Page 14: ...14 Figure 8 Programming Examples for Automatic Setpoint Control Cooling...

Page 15: ...rature is displayed shut off the thermostat for the zone you will be programming by a touching anywhere in the screen then b touching the ON OFF icon See Activating and Deactivating a Zone Thermostat...

Page 16: ...gram has been entered or its program has been turned off Figure 10 Program Schedule Screen Program Selection All Weekdays Shown Entering a New Program For the selected PROG number touch the ON OFF ico...

Page 17: ...as been entered without clearing the entries follow the above procedure up to Entering a New Program When the program you wish to disable is displayed start time and setpoint showing simply touch the...

Page 18: ...rt flashing Use the or icons to change the value if desired then touch the Airzone icon to save the new entry To modify a temperature setpoint touch the displayed cooling setpoint value for about 1 se...

Page 19: ...tomatic setpoint operation If the iQ controller is in AUTO autochangeover mode and Sleep Mode is active Sleep Mode will be automatically cancelled if the system needs to switch from cooling to heating...

Page 20: ...ntilation Mode touch the Airzone icon on the screen twice A mode selection screen will be displayed including the ventilation and sleep icons as shown in Figure 13A Touch the Ventilation icon fan symb...

Page 21: ...place of the temperature value with the and arrows as in Figure 14 below Touch the or arrow to select the number of the zone you wish to access Confirm your selection with a touch to the Airzone icon...

Page 22: ...he Airzone icon to save Note Only one change can be done at a time Once the change has been done it must be confirmed by pressing the Airzone icon After 5 seconds the thermostat will return to the Nor...

Page 23: ...AULT displayed on the top line of the iQ Controller or b Err appearing in place of the time on a zone thermostat as shown in the example in Figure 16 below In general these may indicate a problem with...

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...http www airzoneusa com http www nordyne com...

Reviews: