11
• Press the hand icon so that light is off. You are now in Programmed
Dispense mode.
• Press the foot pedal once to return to the Home screen.
• Press the foot pedal again to dispense your first deposit.
During initial setup, it is normal to dispense
a few shots before your deposit is stabilized.
TIP
Dispense
IMPORTANT SAFETY INFORMATION
All Nordson EFD disposable components, including syringe barrels, cartridges, pistons, tip caps, end
caps, and dispense tips, are precision engineered for one-time use. Attempting to clean and re-use
components will compromise dispensing accuracy and may increase the risk of personal injury.
Always wear appropriate protective equipment and clothing suitable for your dispensing application
.
Do not exceed maximum operating pressure of 100 psi (7.0kg/cm2).
Do not heat syringe barrels or cartridges to a temperature greater than 100°F (38°C).
Dispose of components according to local regulations after one-time use.
Do not clean components with strong solvents (e.g. MEK, Acetone, THF).
Cartridge retainer systems and barrel loaders should be cleaned with mild detergents only.
To prevent fluid waste, use Nordson EFD SmoothFlow
TM
pistons.
For Nordson EFD LLC sales and service in over
30 countries, contact Nordson EFD or go to
www.nordsonefd.com
East Providence, RI USA
USA & Canada: 800.556.3484;
+1.401.431.7000
[email protected]
Dunstable, Bedfordshire, UK
0800 585733; +44 (0) 1582 666334
Ireland 00800 8272 9444
China: +86 (21) 3866 9006
Singapore: +65 6796 9522
The Wave Design is a trademark of Nordson Corporation
©2011 Nordson Corporation 2800GUIDE-01 (7017203) v050311
This equipment is regulated by the European Union under WEEE
Directive (2002/96/EC). See www.nordsonefd.com for information
about how to properly dispose of this equipment.