11

• Press the hand icon so that light is off. You are now in Programmed

Dispense mode. 

• Press the foot pedal once to return to the Home screen. 

• Press the foot pedal again to dispense your first deposit. 

During initial setup, it is normal to dispense 
a few shots before your deposit is stabilized. 

TIP

Dispense

IMPORTANT SAFETY INFORMATION

All Nordson EFD disposable components, including syringe barrels, cartridges, pistons, tip caps, end
caps, and dispense tips, are precision engineered for one-time use. Attempting to clean and re-use
components will compromise dispensing accuracy and may increase the risk of personal injury.

Always wear appropriate protective equipment and clothing suitable for your dispensing application

.

Do not exceed maximum operating pressure of 100 psi (7.0kg/cm2).

Do not heat syringe barrels or cartridges to a temperature greater than 100°F (38°C).

Dispose of components according to local regulations after one-time use.

Do not clean components with strong solvents (e.g. MEK, Acetone, THF).

Cartridge retainer systems and barrel loaders should be cleaned with mild detergents only.

To prevent fluid waste, use Nordson EFD SmoothFlow

TM

pistons.

For Nordson EFD LLC sales and service in over 
30 countries, contact Nordson EFD or go to
www.nordsonefd.com

East Providence, RI USA
USA & Canada: 800.556.3484;   
+1.401.431.7000
[email protected]

Dunstable, Bedfordshire, UK

0800 585733;   +44 (0) 1582 666334

Ireland 00800 8272 9444

[email protected]

China: +86 (21) 3866 9006

[email protected]

Singapore: +65 6796 9522

[email protected] 

The Wave Design is a trademark of Nordson Corporation
©2011 Nordson Corporation 2800GUIDE-01 (7017203)    v050311

This equipment is regulated by the European Union under WEEE 
Directive (2002/96/EC).  See www.nordsonefd.com for information
about how to properly dispose of this equipment.

Summary of Contents for Ultimus IV

Page 1: ...he forward or rear position on either side Remove barrel holder sleeve from holder Insert the 6 mm screw through the barrel holder and bracket and then into the top hole of the front mounting block Tighten screw to secure Insert barrel holder sleeve Part B Install Cable Guide Insert thumbscrew through both the cable guide mount and star washer and then into other mounting block π Position flex arm...

Page 2: ...red light is off TIP 1 Home Jog Hand icon Red Light OFF Program Red Light On Manual 2 Connect Power Foot Pedal 3 Connect the power cord provided to the back of the Ultimus IV and plug into your power source Connect the foot pedal provided to the back of the Ultimus IV Turn unit on On switch is located at the back of the unit An EFD 2800 screen will briefly appear before the Main Menu comes up Powe...

Page 3: ...the syringe barrel and hold barrel next to the flexible cable assembly From Manual mode hand icon light on advance the plunger by pressing the Forward button just until the plunger reaches past the piston By hand insert the plunger into the barrel pressing it into the piston Press the Pullback button to retract barrel until there is just a small gap between barrel and adapter Slide barrel retainer...

Page 4: ...els or cartridges to a temperature greater than 100 F 38 C Dispose of components according to local regulations after one time use Do not clean components with strong solvents e g MEK Acetone THF Cartridge retainer systems and barrel loaders should be cleaned with mild detergents only To prevent fluid waste use Nordson EFD SmoothFlowTM pistons For Nordson EFD LLC sales and service in over 30 count...

Reviews: