WARNING:
All electrically conductive equipment in the spray
area must be grounded. Ungrounded or poorly grounded
equipment can store an electrostatic charge which can give
personnel a severe shock or can arc and cause a fire or
explosion.
Connect the gun ground wire to the red GUN GROUND connector at the
rear panel of the control unit. Refer to the manual shipped with the
Magnum control unit for the location of the ground.
The control unit is shipped with 8-mm and 10-mm tubing connnectors
installed in the input and output ports.
If you want to use to use 0.3125-in. or 0.3750-in. tubing, remove the
connectors, wrap the threads with PTFE tape and reinstall the connectors
on the control unit’s input and output ports.
For further instructions, refer to the manual shipped with the Magnum
control unit.
Gun Ground Connection
Pneumatic Connections