Prodigy
r
Robot Gun
15
Part 1105518
−
02
E
2014
Nordson Corporation
Repair
WARNING:
Allow only qualified
personnel to perform the following tasks.
Follow the safety instructions in this
document and all other related
documentation.
WARNING:
Turn off the electrostatic
voltage and ground the spray gun
electrode before performing the following
tasks. Failure to observe this warning
could result in a severe shock.
Nozzle Replacement
1. See Figure 17. Remove the retaining nut (1)
and nozzle (2).
1
2
Figure 17 Removing Nozzle
2. See Figure 18. Unscrew the nozzle (2) from
the retaining nut (1).
1
2
Figure 18 Nozzle and Retaining Nut
3. Screw a new nozzle into the retaining nut, then
screw the retaining nut back onto the adapter.