Prodigy HDLV Pump Circuit Board Replacement
4
Part 1058046B02
E
2006 Nordson Corporation
Configuring the Circuit Board
See Figure 4. Make sure that SW1 and SW2 are
set as illustrated.
1
2
3
OPEN
4
SW2
1 OPEN
2 OPEN
3 OPEN
4 CLOSED
SW1
Position 1
Figure 4
SW1 and SW2 Settings
for a Manual Powder Spray Systems
Terminating the Prodigy Network
at the Circuit Board
See Figure 5. The circuit board is shipped with a
jumper across pins 2 and 3 of the CAN BUS TERM
terminals. Depending on how many pumps are in
your pump panel, you may have to move the
jumper to pins 1 and 2.
Two Pump System:
Leave jumper across pins 2 and 3.
One Pump System:
Move jumper to pins 1 and 2.
1
W1
CAN BUS TERM
Two Pump System Position
(The board is shipped this way.)
1
W1
CAN BUS TERM
One Pump System Position
Figure 5
CAN BUS TERM Jumper Settings
for Manual Powder Spray Systems
Calibrating the Circuit Board
When you install a new circuit board, use this
procedure to calibrate it to the manifold. If you
have a two-gun system, be sure to perform this
procedure on both Prodigy Manual Gun
Controllers.
1. Turn off the Prodigy Manual Gun Controller.
2. Press and hold the Nordson key, then turn on
power to the Prodigy Manual Gun Controller.
The Configuration screen appears.
Figure 6
Configuration Screen
3. Using the arrow keys or rotary dial, point to the
CALIBRATION selection. Press the
o
key.
The Calibration screen appears.
Figure 7
Calibration Screen
NOTE: Use the arrow keys or rotary dial to move
the cursor to the appropriate setting, then press the
o
key to select it. Use the arrow keys or rotary dial
to change that value, then press the
o
key to
accept the new value and select a new setting.
4. Enter the PUMP FLOW and PATTERN FLOW
A, B, and C calibration numbers from the sticker
on the pump control manifold.