Instruction Sheet

Part 1058046B02

E

 2006 Nordson Corporation

P/N 1058046B02

Prodigy

t

 HDLV

t

 Pump

Circuit Board Replacement

WARNING:  Allow only qualified
personnel to perform the following tasks.
Follow the safety instructions in this
document and all other related
documentation.

WARNING:  Shut off and lock out system
electrical power before performing the
following tasks.  Failure to observe this
warning may result in personal injury.

CAUTION:  Observe the following
cautions when removing or installing the
circuit board.  Failure to observe these
cautions may result in equipment
damage.

S

The circuit board is an electrostatic sensitive
device (ESD).  Wear a grounding wrist strap
connected to the pump panel or other
ground.

S

Turn off and relieve air pressure to the
pumps before removing the circuit board.

S

Do not disconnect the air tubing from the
circuit board.  The transducers are very
delicate and will break if the air tubing is
removed.

Replacing the Circuit Board 

1. See Figure 1.  Close the air supply valve and

trigger the guns to relieve air pressure.

2. Turn off power to the pump panel.  Disconnect

the pump panel from its power source.

O

I

Figure 1

Turning Off Air and Power

Summary of Contents for Prodigy HDLV

Page 1: ...r installing the circuit board Failure to observe these cautions may result in equipment damage S The circuit board is an electrostatic sensitive device ESD Wear a grounding wrist strap connected to the pump panel or other ground S Turn off and relieve air pressure to the pumps before removing the circuit board S Do not disconnect the air tubing from the circuit board The transducers are very deli...

Page 2: ...See Figure 3 Connect the new circuit board s eight transducer air tubes to the appropriate fittings on the pump control manifold s NOTE If there is only one pump control manifold tubes 5 8 are not used Create a service loop with any excess tube length 7 Secure the new circuit board to the pump panel using the four screws 8 Connect the wiring harnesses to the appropriate connectors on the circuit b...

Page 3: ...006 Nordson Corporation 4 3 2 1 Bottom View 8 7 6 5 Bottom View P1 SW1 P2 J4 J3 J2 J1 P3 W1 P6 P5 P4 J5 SW2 PB1 PB2 DS2 DS1 Top View Top View J4 J3 J2 J1 P1 P2 8 7 6 5 4 3 2 1 Pump 1 Manifold Pump 2 Manifold Figure 3 Circuit Board to Pump Control Manifold Connections ...

Page 4: ...ard When you install a new circuit board use this procedure to calibrate it to the manifold If you have a two gun system be sure to perform this procedure on both Prodigy Manual Gun Controllers 1 Turn off the Prodigy Manual Gun Controller 2 Press and hold the Nordson key then turn on power to the Prodigy Manual Gun Controller The Configuration screen appears Figure 6 Configuration Screen 3 Using t...

Reviews: