Prodigy HDLV Generation II Pump, Pump Manifold, and Circuit Board
26
Part 1081195-11
E
2018
Nordson Corporation
Configuring the Circuit Board
See Figure 22. Make sure that SW1 and SW2 are
set as illustrated.
SW1
Position 1
1 2 3
OPEN
4
SW2
1 OPEN
2 OPEN
3 OPEN
4 CLOSED
Figure 22 SW1 and SW2 Settings
for Manual Powder Spray Systems
Terminating the Prodigy Network
at the Circuit Board
See Figure 23. The circuit board is shipped with a
jumper across pins 2 and 3 of the CAN BUS TERM
terminals. Depending on how many pumps are in
your pump panel, you may have to move the
jumper to pins 1 and 2.
Two Pump System:
Leave jumper across pins 2 and 3.
One Pump System:
Move jumper to pins 1 and 2.
1
W1
CAN BUS TERM
1
W1
CAN BUS TERM
Two Pump System Position
(The board is shipped this way.)
One Pump System Position
Figure 23 CAN BUS TERM Jumper Settings
for Manual Powder Spray Systems
Calibrating the Circuit Board
NOTE:
If you have a two-gun system, be sure to
perform this procedure on both Prodigy Manual
Gun Controllers.
When you install a new circuit board, use this
procedure to calibrate it to the manifold.
1. Turn off the Prodigy Manual Gun Controller.
2. Press and hold the Nordson key, then turn on
power to the Prodigy Manual Gun Controller.
The Configuration screen appears.
1401443A
Figure 24 Configuration Screen
3. Using the arrow keys or rotary dial, point to the
CALIBRATION selection. Press the
o
key.
The Calibration screen appears.
1401445A
Figure 25 Calibration Screen
NOTE:
Use the arrow keys or rotary dial to move
the cursor to the appropriate setting, then press the
o
key to select it. Use the arrow keys or rotary dial
to change that value, then press the
o
key to
accept the new value and select a new setting.
4. Enter the PUMP FLOW and PATTERN FLOW
A, B, and C calibration numbers from the sticker
on the pump control manifold.