Prodigy HDLV Generation II Pump, Pump Manifold, and Circuit Board
11
Part 1081195-11
E
2018
Nordson Corporation
Repair
WARNING:
Allow only qualified personnel to perform the following tasks. Follow the safety
instructions in this document and all other related documentation.
Fluidizing Tube Replacement
WARNING:
Shut off and relieve system air pressure before performing the following tasks.
Failure to relieve air pressure may result in personal injury.
Relieve air pressure
and disconnect the
purge air tubing.
1
Loosen the fluidizing
tube access plug and
pull the fluidizing tube
assembly straight out of
the pump body.
2
Seat the new
fluidizing tube
against the red
O-ring.
3
Pull the fluidizing
tube off the access
plug.
Install the fluidizing
tube assemblies into
the pump body. Tighten
the access plugs, then
connect the purge air
tubing.
4
Standard Pump
Retrofit Hi-Flow