Nordson Pro-Meter A2K Quick Start Manual Download Page 7

Troubleshooting 

These troubleshooting procedures cover only the

most common problems. If you cannot solve a

problem with the information given here, contact your

local Nordson

R

 representative for help.

Problem

Possible Cause

Corrective Action

Meter will not cycle

Blocked material path

Ensure material is passing through all hoses.

Dispense valve not opening

Ensure air is on. Inspect dispense valve for binding.

Inspect dispense valve piston for binding. Inspect

dispense valve piston O-ring for wear or damage.

Ensure there is sufficient air pressure. Ensure dispense

valve solenoid is functioning properly.

 Ensure stroke

adjustment bolt is not fully tightened. 

Inlet/outlet valve not opening

Inspect valve for needle/ball binding. Inspect dispense

valve piston for binding. Inspect dispense valve piston

O

ring for wear or damage. Ensure there is sufficient air

pressure. Ensure solenoid valve is functioning properly.

Linear servo actuator not

cycling

Inspect the power and controller connections are

properly fastened. Be sure there is sufficient power to

cycle the linear servo actuator shaft. Reference the

linear servo actuator equipment literature provided with

this manual.

Pressure sensor reading low

pressure

Inspect pressure sensor calibration. Inspect position of

the pressure sensor to ensure the to ensure the part

was installed properly. Ensure the pressure sensor is

properly functioning. Be sure there are no leaks from the

seal cartridge assembly.

Seal cartridge assembly

malfunction

Inspect for sufficient supply pressure. Inspect metering

rod for binding. Inspect bearing for binding. Inspect

metering rod for wear and debris.

Supply equipment not cycling

Ensure there is sufficient air pressure. Reference supply

equipment literature.

Meter 

l

eakage

Loose fitting

Isolate leak and tighten fitting.

Material metering portion

failure

Ensure all fittings and gauges are properly tightened.

S

eal failure

Tighten packing nut on pump. Ensure there is sufficient

lubricant in the wet cup. Replace seal(s), if necessary.

Valve seal failure

Replace seal (s). Replace or repair scored or damaged

needle, if necessary. Replace or repair scored or

damaged sealing face, if necessary.

7

Summary of Contents for Pro-Meter A2K

Page 1: ...em Clear air tubing 0 25 inch 6 35 mm Cups for collecting material during bleed procedure approx 3 0 oz 85 05 g Dispense valve assembly TOOLS REQUIRED FOR INSTALLA TION Ratcheting wrenches Adjustable...

Page 2: ...NG Any material injected into flesh can cause severe injury or death Keep body parts awayfrom material discharge ports If injection occurs seek medical attention immediately WARNING Operating faulty e...

Page 3: ...Circuit Drawing and Customer Product Manual for additional information 4 On systems equipped with a lead lag plate properly adjust the lead lag plate Refer to Lead Lag Adjustment for additional infor...

Page 4: ...electric foot switch may also be utilized to dispense material 22 Repeat steps 2 through 18 as necessary until material is air free 23 From the Cycle Control Screen proceed to the Main Menu HMI Contro...

Page 5: ...to be entered into the control panel 1 Obtain factory serial number from pressure sensor NOTE The serial number is stamped on the pressure sensor 2 Utilize calibration record as a basis to enter contr...

Page 6: ...r on the following HMI Control Panel Screens Interlock Setup Level 1 Setup Menu Level 2 Setup Menu Meter Setup Miscellaneous Pressure Setup Position Setup Pressure Limits Setup Pressure Sensor Calibra...

Page 7: ...nections are properly fastened Be sure there is sufficient power to cycle the linear servo actuator shaft Reference the linear servo actuator equipment literature provided with this manual Pressure se...

Page 8: ...ght date 2017 Nordson and the Nordson logo All other are registered trademarks of Nordson Corporation Pro Meter is a registered trademark of Nordson Corporation All other trademarks are the property o...

Reviews: