Setup and Calibration

 

 

System Unpack 

1.  Attach suitable lifting device to dispense system eye bolts.

 

WARNING: 

Ensure lifting device will safely support dispense system weight of 246 lbs. (111.6 kg). 

 

2.  M12 x 4 mounting holes are provided for installing the dispense system to a table, bench, floor, etc. 

utilizing customer supplied fasteners. Tighten mounting fasteners to specification in accordance with 

manufacturer’s recommendations. 

 

Initial System Startup and Bleed Procedure 

WARNING: 

In addition to the procedures detailed here, refer to the calibration/adjustment procedures in this 

manual and the 

Operator’s Card

 prior to operating the Pro-Meter 

A2K D2K H2K.

 

 

1.  Supply electrical power to Pro-Meter A2K D2K H2K. Refer to the 

Electrical Circuit Drawing

 for additional 

information. 

 

2.  Supply at least 80-100 psi (5.516-6.895 bar) of clean shop air to the air manifold ports. Refer to the 

Pneumatic Circuit Drawing and Customer Product Manual for additional information. 

CAUTION:

 Utilize a desiccant, or equivalent drier, to ensure shop air is free of moisture. 

 

3.  Connect dispense system material supply lines to inlet/outlet valves. Refer to the 

Fluid Circuit Drawing

 

and 

Customer Product Manual 

for additional information. 

 

4.  On systems equipped with a lead/lag plate, properly adjust the lead/lag plate. Refer to 

Lead/Lag 

Adjustment

 for additional information. 

 

5.  Ensure the bleed valves attached to the seal cartridge assemblies are closed. 

 

6.  Log into the HMI Control Panel. Refer to 

HMI Control Panel Login 

below for login information. 

 

7.  Proceed to 

Level 2 Setup

 HMI Control Panel Screen. 

 

8.  Select the 

Level 1 Setup

 push button to proceed to the 

Level 1 Setup Menu

 HMI Control Panel Screen. 

 

9.  Select the 

Valve Setup

 push button to proceed to the 

Valve Setup 

HMI Control Panel Screen. 

 

10. Open the inlet valves by enabling the 

High Vol Inlet

 and 

Low Vol Inlet

 push buttons. 

 

11. Ensure the outlet valves are closed.  

NOTE:

 The 

High/Low Vol Outlets

 push button should not be illuminated on the 

Valve Setup

 HMI Control 

Panel Screen. 

 

12. Supply air pressure to the dispense system. Supply 80-100 psi (0.55-0.69 MPa, 5.52-6.89 bar). 

CAUTION: 

Utilize a desiccant, or equivalent drier, to ensure shop air is free of moisture. 

 

13. Connect clear tubing to bleed valve ports. 

CAUTION: 

Tubing utilized should be 0.25 inch (6.35 mm). 

 

14. Open bleed valves and allow them to remain open until air free material emerges. 

WARNING: 

Utilize a suitable container to collect material bled from bleed valves. 

 

15. Close bleed valves. 

 

 

 

 

 

 

3

Summary of Contents for Pro-Meter A2K

Page 1: ...em Clear air tubing 0 25 inch 6 35 mm Cups for collecting material during bleed procedure approx 3 0 oz 85 05 g Dispense valve assembly TOOLS REQUIRED FOR INSTALLA TION Ratcheting wrenches Adjustable...

Page 2: ...NG Any material injected into flesh can cause severe injury or death Keep body parts awayfrom material discharge ports If injection occurs seek medical attention immediately WARNING Operating faulty e...

Page 3: ...Circuit Drawing and Customer Product Manual for additional information 4 On systems equipped with a lead lag plate properly adjust the lead lag plate Refer to Lead Lag Adjustment for additional infor...

Page 4: ...electric foot switch may also be utilized to dispense material 22 Repeat steps 2 through 18 as necessary until material is air free 23 From the Cycle Control Screen proceed to the Main Menu HMI Contro...

Page 5: ...to be entered into the control panel 1 Obtain factory serial number from pressure sensor NOTE The serial number is stamped on the pressure sensor 2 Utilize calibration record as a basis to enter contr...

Page 6: ...r on the following HMI Control Panel Screens Interlock Setup Level 1 Setup Menu Level 2 Setup Menu Meter Setup Miscellaneous Pressure Setup Position Setup Pressure Limits Setup Pressure Sensor Calibra...

Page 7: ...nections are properly fastened Be sure there is sufficient power to cycle the linear servo actuator shaft Reference the linear servo actuator equipment literature provided with this manual Pressure se...

Page 8: ...ght date 2017 Nordson and the Nordson logo All other are registered trademarks of Nordson Corporation Pro Meter is a registered trademark of Nordson Corporation All other trademarks are the property o...

Reviews: