Hot melt application head EP 30
19
P/N 397191B
E
2005 Nordson Corporation
EP 30
Technical Data
Electrical Data
Operating voltage
230 V
DC
Operating voltage frequency
50/60 Hz
Power consumption
Refer to ID plate
Degree of protection
IP 30
Voltage for solenoid valve
24 V
DC
Type of heating
Electrical resistance heating elements
Possible temperature sensors
FeKo thermal
element
Ni 120
Pressure Data
Control air pressure
5 to 6 bar
0.5 to 0.6 MPa
72.5 to 87 psi
Max. adhesive pressure at inlet
100 bar
10 MPa
1450 psi
Max. control module locking pressure
(without compressed air)
70 bar
7 MPa
1015 psi
Temperatures
Max. ambient temperature
60
°
C
140
°F
Max. operating temperature
250
°
C
482
°F
Duration of heatup
Approx. 20 min
Dimensions and Weights
Dimensions
Refer to technical drawing
Weight
See consignment note