© 2022 Nordson Corporation
3-2
Spray Gun Installation
See Figure 3-2 and Figure 3-3 for spray gun connection illustrations.
1.
Connect the 6-mm pattern air tubing to the quick-disconnect fitting (1) in the gun base.
Connect the other end to the pattern air tubing on the fitting located on the pump
control unit.
2.
Connect the 4-mm clear electrode air wash tubing to the quick-disconnect fitting (4) in
the bottom of the gun base. Connect the other end to the electrode air wash tubing on
the 90° flow control fitting on top of the pump control unit.
3. Connect the powder hose over the barbed end of the hose connector (2).
4. Connect the gun cable to the gun cable receptacle (3).
5. Route the powder hose, gun cable, and air tubing to the system controller. Take care
to not kink, bind, or deform the powder tubing.
1
3
2
4
Figure 3-2 Spray Gun Connections
Summary of Contents for Encore Select HD