System Setup
3-5
Part 1604858-01
E
2013 Nordson Corporation
System Connections
Single/Dual Controller Connections
Make connections as shown in Figure 3-4. See Figure 3-5 for remote
trigger, conveyor interlock, and remote lockout connections.
Connect the ground cable with clamp to the ground stud (1) and clamp to a
true earth ground or a grounded booth base.
Use spiral-cut tube wrap to bundle the flow and atomizing air tubing to the
pumps, and the gun cable and electrode air wash tubing to the guns. Route
the tubing and cables to prevent damage and kinking.
NOTE:
An optional 0.3 micron air filter is available for use with single and
dual controllers. Refer to
Parts
for ordering information.
4
L1
L2
GND
1
2
3
5
6
7
8
1
2
1
2
2
(BROWN)
(BLUE)
(GRN/YEL)
L1
L2
GND
3
(BLUE)
2
1
(GRN/YEL)
4
5
6
7
8
Dual Controller
Single Controller
Single/Dual Automatic Gun Controller Connections
1. Ground stud
2. Auxiliary power or external trigger
3. Controller power cord (15ft)
4. Atomizing air (blue, 8mm, to pump)
5. Air supply (blue, 10mm)
6. Flow air (black, 8mm, to pump)
7. Gun cable
8. Electrode air wash (clear,
4mm, to gun)
Remote Connections for Single/Dual Controllers
See Figure 3-5. Bring the trigger and interlock cables into the enclosure
through the AUX or VBF strain reliefs and connect them to the J3 terminals
on the main control board(s). The Trigger A, Conveyor Interlock, and
Lockout circuits are all sinking circuits. These circuits operate on 10 mA
±
1
.
Summary of Contents for Encore LT Automatic
Page 4: ...Change Record ii Part 1604858 01 E 2013 Nordson Corporation...
Page 8: ...Table of Contents vi Part 1604858 01 E 2013 Nordson Corporation...
Page 12: ...Safety 1 4 Part 1604858 01 E 2013 Nordson Corporation...
Page 20: ...Description 2 8 Part 1604858 01 E 2013 Nordson Corporation...
Page 34: ...System Setup 3 14 Part 1604858 01 E 2013 Nordson Corporation...
Page 44: ...Operation 4 10 Part 1604858 01 E 2013 Nordson Corporation...
Page 63: ...Wiring Diagrams 7 1 Part 1604858 01 E 2013 Nordson Corporation Section 7 Wiring Diagrams...
Page 64: ...Wiring Diagrams 7 2 Part 1604858 01 E 2013 Nordson Corporation...