410x
Color Change
4109
Clean cycle aborted arch
clean operation
−
waiting on
park release
Clean cycle detected an abort
−
waiting for
user to press park to release.
4110
Clean cycle aborted by user
action
−
park release
detected
Clean cycle aborted by user
−
part release
was detected.
4111
Clean cycle aborted detected
machine lockout/watchdog
A machine malfunction aborted the cleaning
operation.
CAN Network Errors
Error
Code
Message
Cause/Correction
101
CAN bus fault detected
Hardware error. Check the CAN cable for shorts. If the
cable is good, replace the PC104 CAN card.
102
CAN receive buffer overflow
Host CAN interface received too much data and could
not process it quickly enough. Reboot the system.
103
Message timeout
Remote CAN device did not respond to a direct request
in the allotted time. Check the gun card or iFlow card.
104
Went offline
Normal operational message. The user will see this
message if the booth exhaust fan is shut off, which
removes power from gun cards, or if the gun card is
disconnected, or if the iFlow module is disconnected
from the CAN network.
105
Returned to online
Normal operational message. No action required.
107
Communications errors
These error messages indicate that communications on
the iControl CAN bus may be having problems.
Troubleshooting should include verification of all CAN
cable connections and grounding, and gun cable
connections and continuity. CAN errors can also be
caused by individual gun cards or the iControl PC to
PC104 card interface. These errors do not indicate a
specific device failure as all devices are in parallel on the
CAN bus.
108
109
110
111
112
113
Obsolete
Summary of Contents for Encore HD iControl System
Page 4: ...Change Record ii Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 8: ...Table of Contents vi Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 22: ...System Overview 2 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 40: ...Installation 3 18 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 88: ...Parts 6 10 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 90: ...Wiring Diagrams 7 2 Part 1603054 02 E 2015 Nordson Corporation O b s o l e t e ...
Page 92: ...O b s o l e t e ...