Advanced Features (Memory)
The Ultimus high precision dispenser allows you to store the dispense time, pressure, and vacuum settings for up to
16 different job programs. Programs are saved even with power removed and will remain in storage unless changed
or erased intentionally.
Job programs are identified as Memory 1 through Memory 16.
NOTE:
Dispense time is automatically adjusted when you select an individual job program. Settings for pressure and
vacuum are stored and can be displayed but you need to manually adjust the pressure and vacuum regulator knobs
to match the stored settings for these values.
To Save a Job Program
1. From TIMED or TEACH mode, set the dispense time, air pressure, and vacuum settings to create a correct
deposit size. When you are in TEACH mode, press SAVE after you create your settings, then return to TIMED
mode.
2. Press MENU. Use the up / down arrows to scroll to SAVE JOB. Press SELECT.
3. Use the up / down arrows to select the correct job program in which to save these settings (example, Memory 1
or Memory 2).
Remember:
to prevent accidental data loss, review the contents of each job program before selecting and
storing a new job into memory.
4. Press SAVE. This automatically saves the settings in the job program.
To Work in a Saved Job Program
1. Press MENU. Use the up / down arrows to highlight MEMORY. Press SELECT.
2. Use the up / down arrows to scroll through the individual jobs until you reach the correct Memory number.
3. Press and hold SETTINGS to see the stored pressure and vacuum settings for the job.
Remember:
Dispense time automatically adjusts when you select a job program. Releasing the SETTINGS
button displays the current values for pressure and vacuum, not the stored values. To retrieve the stored values,
manually adjust air pressure and vacuum based on the pressure and vacuum shown when you press Settings.
4. Press the foot pedal or finger switch to activate the dispense cycle. The Ultimus will automatically make the
deposit based on the settings in the selected job program.
5. To escape from Memory, press MENU. Then press TIMED to return to the Home screen. At this point, you are
still in the current memory setting for the previous job program, but you are free to change time, pressure, and
vacuum without impacting the stored settings in memory.
Ultimus I–II High Precision Fluid Dispensers
20
www.nordsonefd.com [email protected]
800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.