How to enable/disable low air pressure alarm:
Step 1
Press MODE
button and scroll to STEADY .
Step 2: Press and hold
until Aon
or Aof
is visible.
Step 3
Press
or
button to toggle between Alarm On
or
Alarm OFF
.
Step 4
Press MODE
button to exit.
How to select PSI or BAR pressure readout:
Step 1
Press MODE
button and scroll to STEADY.
Step 2: Press and hold
until Aon
or Aof
is visible.
Step 3
Press
button one time
Step 4
Press
or
button to toggle between
for BAR, and
for Psi.
Psi Format: 0. to 101.
BAR Format: 0.0 to 7.0
Step 5
Press MODE
button to exit.
How to enable/disable CC INIT I/O as an external
alarm input:
Step 1
Press MODE
button and scroll to STEADY.
Step 2: Press and hold
until Aon
or Aof
is visible.
Step 3: Press
two times.
Step 4: Press
or
button to toggle between CCI
or ALI
CC INIT function is:
CCI:
Contact Closure initiate input
ALI:
External alarm input
Step 5
Press MODE
button to exit.