14
How to use the TEACH mode:
Step 1
Press MODE
button and scroll to TEACH.
Step 2
Press and hold CYCLE
button or depress the foot pedal in the TEACH
mode. LED display will begin “flashing” before TEACH function begins.
Step 3
Add incremental time by continued press and hold of CYCLE
button
or depress and hold the foot pedal.
Step 4
To fine tune programmed pulse time, press
or
to decrease/increase
time..
Step 5
Press both
to .000 out time to and restart the TEACH process.
How to purge with or without nozzle air:
Press MODE
button and scroll to PURGE.
To PURGE without Nozzle Air:
Step 1
Press
or
to display
.
Step 2
Press
button or depress foot pedal to purge.
To PURGE with Nozzle Air:
Step 1
Press
or
to toggle to
for both valve actuation/nozzle air purge.
Step 2
Press
button or depress foot pedal to purge.
How to adjust nozzle air delay:
Factory default is set to .240 seconds. Full range of nozzle air delay is .000 to 9.99
seconds. To change nozzle air delay:
Step 1
Press MODE
button and scroll to SETUP.
Step 2
Press
button and hold for 3 seconds. Nozzle Air Delay time value will
begin to flash to distinguish between actuation time.
Step 3
Press
or
to decrease/increase Nozzle Air Delay.
Press both
to .000 time.
Step 4
Press
to return to Time / Setup mode.