ValveMate 7100 Controller
20
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Air Connections
Air Output Connection
Connect the valve actuating air hose to the AIR OUT
1
at the back of
the ValveMate 7100 controller.
Air Input Connection
Connect the ValveMate 7100 to plant air by first installing the included
EFD five-micron filter regulator (P/N 7002002) on your air supply.
Install the air tee with push-in fitting (P/N 7016230) in the output of the
filter regulator. (Included with EFD tank/cartridge reservoirs.)
3 m (9 ft) of 6 mm OD air line is supplied. Using the 6 mm push-in
fitting supplied, connect one end to the P/N 7016230 air tee. Connect
the other end of the air line by pushing it firmly into the AIR IN
2
connector on the ValveMate 7100 until it bottoms out. Be sure that the
line is inserted all the way into the fitting.
Set the pressure at the P/N 7002002 filter regulator to 4.8 bar (70 psi).
The quick-connect on the air tee is used to provide air pressure to the
air pressure regulator on EFD fluid reservoirs. This connection will be
made at a later step in the setup.
Important:
The air output push-in fitting has an internal safety stop valve. Make certain the valve air
hose is fully inserted into the fitting to allow proper air flow.
1
2