PICO
Toµch
Series Controllers
62
www.nordsonefd.com [email protected]
+1-401-431-7000 Sales and service of Nordson EFD dispensing systems are available worldwide.
Appendix A, Remotely Operating the Controller
(continued)
Valve (Driver) (continued)
Command
Description
Command Format
Sample, with Output
After [Enter]
cycl
Cycles the valve (mimics
the CYCLE icon on the
touchscreen)
0cycl
Cycle OFF
1cycl
Cycle ON
NOTE:
Each Cycle ON command must be
followed by a Cycle OFF command.
1cycl
[Enter]
Cycle: ON
0cycl
[Enter]
Cycle: OFF
dpwr
Sets the valve power
control
0dpwr
Valve power OFF
1dpwr
Valve power ON
0dpwr
[Enter]
Valve Driver Power: OFF
1dpwr
[Enter]
Valve Driver Power: ON
plok
Sets the duration of the
PULSE OK Time I/O pin
output
AAAplok
Where
AAA
= PULSE OK Time in ms
050plok
[Enter]
Pulse OK Time Adj:050
drvo
Sets the driver
configuration at power
up to ON
drvo
drvo
[Enter]
Power Mode: ON at boot up
drvf
Sets the driver
configuration at power
up to OFF (default)
drvf
drvf
[Enter]
Power Mode: Default
sdr1
Sets OPEN, CLOSE, and
COUNT in one command
xxxx.xx,yyyy.yy,zzzzzsdr1
Where
xxxx.xx
is the OPEN time (in ms)
Where
yyyy.yy
is the CLOSE time (in ms)
Where
zzzzz
is COUNT
0002.23,0005.77,00535sdr1
[Enter]
0002.23,0005.77,00535