1. 

Install the feed tube from the fluid reservoir to 
the inlet fitting and tighten the compression nut 
to secure. The location of the inlet fitting can 
be changed by removing the two fluid body 
retainer screws and fluid body. Follow the service 
instructions to reinstall the fluid body with the inlet 
fitting in the desired position.

2. 

Apply air pressure to the fluid reservoir. Start with 
a low setting of 1.4 bar (20 psi). If using an EFD 
fluid reservoir, refer to the User’s Guide for further 
instructions.

Introduction

The 752V-HL (#7021415) hand-operated dispense gun is a rugged, industrial, lever-actuated fluid dispensing valve. 
The valve incorporates a quick change fluid body for fast and easy maintenance. The fluid inlet fitting for 1/4" OD 
feed tubing and an assortment of dispensing tips are included.

Typical System Setup

3. 

Install an appropriate size dispensing tip on 
the outlet tip adapter. Use large tips for high 
viscosity materials and small tips for low viscosity 
materials.

4. 

Press the hand lever to begin fluid flow. Release 
the lever to stop fluid flow.

5. 

To achieve the desired flow, change the size of 
the dispensing tip or adjust the reservoir fluid 
pressure.

#7020105

Hand-lever 

valve stand

#7010004

1.0 liter tank 

accommodates a one 

pound bottle

#7002002
5-micron filter/regulator for 
clean, dry filtered factory air

For dispensing with 
cyanoacrylates, order #7016548 
with coalescing filter.

Shutoff valve

Reviews: