background image

Square Wave 745NC Non-Contact Dispense Valve

6

www.nordsonefd.com   [email protected]

   +1-401-431-7000    Sales and service of Nordson EFD dispensing systems are available worldwide.

5.  Connect the 745NC Square Wave valve with a 4 watt solenoid to a 

ValveMate

 8000 controller.

*IMPORTANT NOTE:

 Only a 745NC valve installed with a 4 watt 

solenoid can be used with the ValveMate 8000 controller.
a.  Follow steps 1 through 4 on page 4.
b.  Connect the 745NC valve to the ValveMate 8000 controller 

using the solenoid wires supplied. See Figure 2.

NOTE:

 Installing the Dispense Valves 

The ValveMate 8000 is supplied with an installation manual. The 
manual will explain the operation of the ValveMate 8000 and input / 
output connections for 745NC valve initiate.

6.  Purge valve:

a.  Set reservoir pressure to 0.275 bar (4 psi) as a minimum starting point.
b.  Remove retaining nut to release nozzle plate.
c.  Set valve stroke between 10–20 on reference ring.
d.  Cycle valve at 50Hz minimum at 50% duty for purging.

CAUTION

CAUTION

 

for 24 watt solenoid only:

 Minimum dispensing frequency is 

50Hz. Operating frequencies lower than the minimum requirement will cause 
solenoid failure.

e.  Cycle valve until fluid lines are free from air.
f.  Replace nozzle plate / retaining nut onto valve.

7.  Set desired flow rate:

a.  Set reservoir pressure to 0.275 bar (4 psi) as a minimum starting point.
b.  Set valve stroke control to 1 hash mark (one click from zero) on stroke 

reference ring as starting point.

c.  Set frequency / duty cycle to 100Hz and 50% duty to establish initial 

dispense volume. Adjust frequency/duty cycle to achieve desired flow 
rate.

NOTE:

 Refer to Figure 3 on opposite page as a guide for dispensing 

volume as a function of frequency and fluid pressure.

Figure 2

NOTE:

 Use the blue and 

brown wires of the bullet 
solenoid cable for BackPack 
valve actuation. The wires are 
not polarized.

Operation of a Spike and Hold Driver Circuit

Summary of Contents for 745NC

Page 1: ...Square Wave 745NC Non Contact Dispense Valve Operating Manual Electronic pdf files of Nordson EFD manuals are also available at www nordsonefd com...

Page 2: ...ur no compromise quality standards If you feel that you are not receiving all the support you require or if you have any questions or comments I invite you to write or call me personally Our goal is t...

Page 3: ...ce Maximum cycle time 24 W solenoid 15 ms open and close once 4 W solenoid Continuous Minimum dispensing frequency 24 W solenoid 50Hz 4 W solenoid Continuous Maximum dispensing frequency 24 W solenoid...

Page 4: ...o 5 VDC for the remaining period that the valve is open CAUTION Failure to reduce the voltage will result in permanent damage to the actuation solenoid if the valve is left on longer than 30 ms To avo...

Page 5: ...spike voltage to actuate the valve The spike and hold driver circuit will apply the spike voltage from 1 to 30 ms before transitioning to the hold voltage CAUTION Not using a spike and hold driver ci...

Page 6: ...ning nut to release nozzle plate c Set valve stroke between 10 20 on reference ring d Cycle valve at 50Hz minimum at 50 duty for purging CAUTION CAUTION for 24 watt solenoid only Minimum dispensing fr...

Page 7: ...re 3 Dispensing volume as a function of frequency and pressure 101 6 m 0 004 nozzle Bullet solenoid cable NOTE Use the blue and brown wires of the bullet solenoid cable for BackPack valve actuation Th...

Page 8: ...t seal groove is facing upwards and expanded fully in its groove 6 Replace with new needle assembly Insert into actuation body ensuring that piston seal is not damaged 7 Reassemble the upper stroke co...

Page 9: ...the bullet solenoid 4 Engage wrench flats on bullet solenoid and rotate counterclockwise to remove When loose pull bullet solenoid up slowly to release 5 Place a light film of PTFE grease on O rings...

Page 10: ...S 7028729 Chamber seat plate 7028728 Nozzle 0 004 7028731 Nozzle 0 005 7028732 Nozzle 0 006 7028733 Nozzle 0 007 7028734 Actuator body 7028735 Fluid inlet fitting 7020671 Fluid body O ring Buna N 7028...

Page 11: ...ged Bullet solenoid may not be actuating Replace solenoid Steady drip A steady drip can be caused by a worn needle and seat or a particle holding the needle off the seat Clean and inspect the needle a...

Page 12: ...incompatible with equipment when the equipment is installed and operated in accordance with factory recommendations and instructions Nordson EFD will repair or replace free of charge any defective pa...