Prior to installing this valve, please 
read the associated reservoir and 
valve controller operating instructions 
to become familiar with the operation 
of all components of the dispensing 
system.

Do not thread fluid inlet fittings too far 
into the valve. Doing so can obstruct 
the piston shaft, causing leakage, poor 
dispensing performance, and damage to 
the valve.

CAUTION

1. 

Connect the fluid feed hose to the 
fluid inlet fitting (#7021038) installed 
for use with 3/8" OD tubing and 
reservoir.

2. 

Connect the fluid supply line to 
reservoir. The reservoir can accept 
either 1/4" OD or 3/8" OD tubing 
using #7020159 supplied.

3. 

 Connect valve control air hose to 
ValveMate™ 8000 (solenoid pack) 
used to control valve open time.

4. 

Install nozzle to the valve output.

5. 

Fill reservoir by pouring fluid directly 
into tank liner or manufacturer’s bottle 
placed inside reservoir. Secure cover 
prior to setting pressure.

6. 

Set reservoir pressure to low for thin 
fluids and higher for thick fluids.

7. 

Place a cup under the dispensing tip 
or nozzle and actuate the valve until 
fluid lines, valve and dispensing tip 
are free of air.

8. 

Set desired flow rate by adjusting 
fluid reservoir pressure or changing 
dispensing tip or nozzle. 

Installation

Important Note: Set desired deposit size by adjusting valve open time. Refer to valve controller operating manual.