20
Operation
4.4.2.4 Needle Z Offset
To teach needle to height sensor Z offset (Figure 4-9 and Figure 4-10):
1. Select the Teach Center Method.
Figure 4-9 Needle to Height Sensor Z Offset
2. Use the position controls to move the camera crosshairs to the teaching point(s) on the
tactile sensor and click on
Teach
.
3. Click on
Done
when finished.
The machine will now calculate the
offset measurements for the vertical
and the front/rear or left/right tilts.
The tilt direction is specified in the
Setup Valves window (Figure 3-8).
The Z Offset Summary will appear
4. Click on
Front
to see the offset values
for the front tilt.
5. Click on
Rear
to see the offset values
for the rear tilt.
6. Click on
OK
to close the summary.
Figure 4-10 Needle to Height Sensor Z Offset
Summary
NOTE
In this example, the left and right tilt values are grayed out. If the tilt direction
selected in Setup Valves is left/right, these values would be active and the front
and rear values would be grayed out.
Summary of Contents for Spectrum S-9 Series
Page 1: ...Spectrum Series Single Axis Automatic Tilt Mechanism Owner s Manual...
Page 6: ......
Page 10: ......
Page 34: ......