17
GB
0D[LPXPIXHOOHQJWKFP
37 cm
Flue outlet
Top and rear
)OXHPP
Outer Ø 150 mm
*Alternative versions
exsists due to National
requirements
)OXHJDVWHPSHUDWXUHDWÀXH
FRQQHFWRU&
388
'UDIWDWÀXHFRQQHFWRU
UHFRPPHQGHG3D
15 - 25
1RPLQDOKHDWRXWSXWN:
5,8
(ႈFLHQF\
79
&2#2
0,07
)OXHJDVWHPSHUDWXUH&
324
'UDIW3D
15
Fuel recommended
:RRG
)XHOOHQJWKUHFRPHQGHGFP
30-35
)XHOFKDUJHNJ
1,20
5HIXHOLQJLQWHUYDOPLQXWHV
45
Operation
Intermittent*
,QWHUPLWWHQWFRPEXVWLRQUHIHUVWRQRUPDOXVHRID¿UHSODFHLHQHZ
wood is inserted when the previous load has burned down to ember
:DUQLQJ,IWKHUHTXLUHPHQWVIRUYHQWLODWLRQDUH
127FRPSOLHGZLWKWKHFRROLQJDLUÀRZDURXQGWKH
SURGXFWZLOOEHFRQVLGHUDEO\UHGXFHGDQG
WKHSURGXFWFDQRYHUKHDW
7KLVFDQFDXVHD¿UH
3. Distance to combustible material
Ensure that the safety distances are respected
(FIG 1A, 1B and 1C).
:KHQFRQQHFWLQJDVWHHOFKLPQH\WRWKHWRSRXWOHWXVH
the security distances required from the manufacturer.
$VVHPEO\
•
FIG 2 -
Rear air connection
•
FIG 3 -
Bottom air connection
•
),*5HDUÀXHFRQQHFWLRQ
•
),*7RSÀXHFRQQHFWLRQ
•
FIG 6, 7 - Thermotte plates disassembling
•
FIG 8 - Air vent control
2SHUDWLQJFRQWURO
:KHQWKHVWRYHLVLQDQXSULJKWSRVLWLRQDQGSULRU
to connecting it, control that all functions are easy to
manoeuvre and appear satisfactory.
&RQQHFWLQJWKHÀXH
3OHDVHEHDZDUHZKHQFRQQHFWLQJWKHPPÀXHWR
WKHVPRNHGRPHWKDWWKHÀXHLVSODFHGRXWVLGHWKHÀXH
outlet collar. *Alternative versions exsists due to
1DWLRQDOUHTXLUHPHQWV)RUWKHÀXHFRQQHFWLRQWRWKH
chimney, follow the recommendations from the chimney
manufacturer.
:HUHFRPPHQGDPD[LPXPFKLPQH\ZHLJKWRI
NJ
/LJKWLQJWKH¿UHIRUWKH¿UVWWLPH
:KHQWKHVWRYHLVDVVHPEOHGDQGDOOLQVWUXFWLRQVKDYH
EHHQREVHUYHGD¿UHFDQEHOLW
Take care when inserting logs into the burn chamber,
in order not to damage the Thermotte plates. Please
note that there might be some humidity in the insulation
SODWHVZKLFKFDQUHVXOWLQDVORZHUEXUQUDWHWKH¿UVWIHZ
times the stove is used. These will be resolved once the
humidity has evaporated.
,WLVDGYLVDEOHWRYHQWLODWH
WKHURRPZHOOZKHQ¿ULQJIRUWKH¿UVWWLPHDVWKH
YDUQLVKRQWKHVWRYHPD\UHOHDVHVRPHVPRNHRU
smell.
Both the smoke and smell will disappear and are
not hazardous.
/LJKWLQJD¿UH
Insert small dry pieces of kindling wood,open the air
YHQWFRQWURODQGLJQLWH:KHQWKHÀDPHVDUHVWDEOHDQG
the chimney is warm, the air supply is regulated with the
air vent control.
:KHQWKHUHLVDJORZLQJOD\HURIDVKQHZZRRGORJV
can be inserted. Pull the hot ember to the front of the
combustion chamber when inserting new logs so that
WKHZRRGLVLJQLWHGIURPWKHIURQW7KH¿UHVKRXOGEXUQ
ZLWKEULJKWDQGOLYHO\ÀDPHV
8VLQJWKHVWRYHZLWKORZFRPEXVWLRQHႇHFWDQG¿ULQJ
around the clock increase pollution as well as the risk
IRUD¿UHLQWKHFKLPQH\1HYHUDOORZWKHVWRYHRUÀXH
WREHFRPHJORZLQJUHG7XUQRႇWKHDLUYHQWFRQWURO
should this happen. Regulation of the air vent control
takes some experience, but after a little while a natural
UK\WKPIRUWKH¿UHZLOOEHIRXQG
,03257$17$OZD\VUHPHPEHUWRRSHQWKHDLU
YHQWFRQWUROZKHQQHZZRRGORJVDUHLQVHUWHG
LQWRDKRWEXUQFKDPEHU/HWWKHÀDPHVJHW
HVWDEOLVKHGRQWKHZRRGEHIRUHWKHDLUVXSSO\LV
reduced.
:KHQWKHGUDXJKWLQWKHFKLPQH\LVORZDQG
WKHYHQWVDUHFORVHGWKHJDVIURPWKH¿UHZRRG
FDQEHLJQLWHGZLWKDEDQJ7KLVFDQFDXVH
GDPDJHVWRWKHSURGXFWDVZHOODVWKHLPPHGLDWH
HQYLURQPHQW
Summary of Contents for SN-ME000-014
Page 14: ...48 FIG 3a 1 O 2 3 2...
Page 15: ...49 FIG 3b 1 2 3 4 TORX TOR FIG 3c 1 2 TORX 21 30011 408 x4 22 ME000 550 TO...
Page 18: ...52 1 2 3 4 4 mm FIG 5b 2...
Page 21: ...55 FIG 6b FIG 6c...
Page 22: ...56 FIG 6d FIG 6e...
Page 24: ...58 1 2 FIG 7a ME FIG 6a 6f...
Page 32: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...