Nordpeis S-18 F User Manual Download Page 15

Some advice in case of combustion problems

Error

Explanation

Solution

No draught

The chimney is blocked.

Contact a chimney sweeper / dealer for more information or clean 

the flue, smoke baffle and burn chamber.

The flue is sooty or there is accumulated soot on the 

smoke baffle.
The smoke baffle is wrongly positioned.

Verify the assembly of the smoke baffle - see assembly instructions.

The insert 

release smoke 

when ligh-

ting the fire 

and during 

combustion

Downdraught in the room caused by no draught, that the 

house is too “air tight”.

Light the fire with an open window. If this helps, more/bigger vents 

must be installed in the room.

Downdraught in the room – caused by extractor and/or 

central ventilation system that pulls too much air out of 

the room.

Turn off/regulate extractor and/or other ventilation. If this helps, more 

vents must be installed.

The flues from two fireplaces/stoves are connected to the 

same chimney at the same height.

One flue must be repositioned. The height difference of the two flue 

pipes must be of at least 30 cm. 

The flue is in a declining position from the smoke dome to 

the chimney.

The flue must be moved so that there is an inclination of at least 

10º from smoke dome to chimney. Possibly install a smoke suction 

device*.

The flue is too far into the chimney.

The flue must be reconnected so that it does not enter into the chim-

ney but ends 5 mm before the chimney inner wall. Possibly install a 

smoke suction device*.

Soot hatch in the basement or attic that is open and thus 

creating a false draught.

Soot hatches must always be closed. Hatches that are not tight or 

are defected must be changed.

Damper/top draught vents or doors on fireplaces that are 

not in use are open and create a false draught.

Close damper, doors and top draught vents on fireplaces that are 

not in use.

An open hole in the chimney after that a fireplace has 

been removed, thus creating a false draught.

Holes must be completely sealed off with masonry.

Defect masonry in the chimney, e.g. it is not airtight 

around the flue pipe entry and/or broken partition inside 

the chimney creating a false draught.

Seal and plaster all cracks and sites that are not tight.

The cross-section in the chimney is too large which 

results in no or very low draught.

The chimney must be refitted, possibly install a smoke suction 

device*.

The cross-section in the chimney is too small and the 

chimney cannot carry out all the smoke.

Change to a smaller fireplace or build new chimney with a larger 

cross section. Possibly install a smoke suction device*.

The chimney is too low and hence a poor draught.

Increase the height of the chimney and/or install a chimney cap/

smoke suction device*.

The fireplace 

releases smoke 

inside when 

it is windy 

outside.

The chimney is too low in relationship to the surrounding 

terrain, buildings, trees etc.

Increase the height of the chimney and/or install a chimney cap/

smoke suction device*.

Turbulence around the chimney due to the roof being too 

flat.

Increase the height of the chimney and/or install a chimney cap/

smoke suction device*.

The fireplace 

does not heat 

sufficiently.

The fireplace combustion receives too much oxygen due 

to a leakage under the lower border of the insert or too 

strong chimney draught. Difficult to regulate the combus-

tion and the wood burn up too quickly.

Any possible leakage must be sealed off. A draught regulator or 

possibly a damper can reduce the chimney draught. NB! A leakage 

of only 5 cm2 is enough for 30% of the heated air to disappear.

Too much 

draught

The smoke buffer is wrongly positioned.

Verify the positioning of the smoke buffer – see assembly instruc-

tions.

In case of using oven-dried wood, this requires less air 

supply than when using normal wood.

Turn down the air supply.

The gaskets around the door are worn and totally flat.

Replace the gaskets, contact your dealer.

The chimney is too large.

Contact chimneysweeper or other professional for more details.

The glass is 

sooty

The wood is too wet.

Only use dry wood with a humidity of maximum 20%.

The air vent control is closed too tightly.

Open the air vent control to add air to the combustion. When new 

wood logs are inserted all vent controls should be completely 

opened or the door slightly opened until the flames have a good 

take on the wood.

White glass

Bad combustion (the temperature is too low).

Follow the guidelines in this user guide for correct combustion.

Using wrong material for combustion (such as: painted 

or impregnated wood, plastic laminate, plywood etc).

Ensure to use only dry and clean wood.

Smoke is rele-

ased when the 

door is opened

A levelling out of pressure occurs in the burn chamber.

Open the air vent control for about 1 min before opening the door – 

avoid opening the door too quickly.

The door is opened when there is a fire in the burn 

chamber.

Open the door carefully and/or only when there is hot ember.

White smoke

The combustion temperature is too low.

Increase the air supply.

The wood is humid and contains water damp.

Ensure to use only dry and clean wood.

Black or grey/

black smoke

Insufficient combustion.

Increase the air supply.

15

GB

Summary of Contents for S-18 F

Page 1: ...S 18 F 9 Product no IN 0S18F Test report No RRF 29 16 4290 Last updated 03 01 2018 GB User manual NO Brukerveiledning 2...

Page 2: ...trekk fordi skorsteinen ikke blir godt nok oppvarmet I slike tilfeller kan det l nne seg ta kontakt med kynding personell for vurdering av eventuelle tiltak For kraftig trekk kan avhjelpes med en tre...

Page 3: ...Hold alle luftinntak fri for forbrenningen fri for tildekking Opprettholdes IKKE kravet til ventiler vil effekten av varmesirkulasjonen bli vesentlig redusert og overoppheting kan oppst I verste fall...

Page 4: ...d en fj r nederst i venstre hj rne av d ren Hekt av fj ren og skru ut umbrakoskruen som holder fj rstaget i d ren Selvlukkemekanismen er n deaktivert A Tenning luftventilen A Kontroll av funksjoner N...

Page 5: ...bytte etter noen r Slitasjen er direkte p virket av bruken av ildstedet Nordpeis gir ett rs garanti p deisse delene Utover denne garantiperioden kan delene kj pes Skulle det v re behov for erstatte e...

Page 6: ...vil det v re for lite tilsig av luft til at temperaturen i brennkammeret blir h y nok Ved for lav temperatur i brennkammeret forsvinner gass uforbrent ut igjennom pipen For lite luft kan ogs medf re...

Page 7: ...d eller bygg ny pipe med st rre tverrsnitt Evt montering av r yksuger For lav pipe som gir d rlig trekk k pipeh yden og eller monter pipehatt r yksuger Ildstedet ryker inne n r det er vind ute Pipen l...

Page 8: ...ligheter for ildsted og r ykr r Er ildstedet sikret nok tilf rsel av forbrenningsluft via lufteventiler Er r ykr ret montert i skorstenen etter skorstensprodusentens anvisninger Er skorstenen egnet fo...

Page 9: ...e carefully read the user manual and follow the instructions 3 Integrated or defined convection openings may never be reduced or partially obstructed This may lead to overheating which again can cause...

Page 10: ...to the latest European requirements and also to the Norwegian standard NS 3058 and NS 3059 which include particle tests However several European countries have local regulations for installation of f...

Page 11: ...imum safety distances are fullfiled FIG 1 When connecting a steel chimney to the top outlet use the security distances required by the manufacturer Important When placing the insert on a combustible f...

Page 12: ...r to avoid injuries please be aware that the surfaface may become hot during operation and extra care need to be taken to avoid skin burn A Flue outlet collar S 18F is delivered standard with a top fl...

Page 13: ...hich will require to be exchanged after some years The wear time will depend on the individual use of your product Nordpeis offers a one year warranty on these parts After this replacements can be pur...

Page 14: ...emely fine wood apart from when lighting a fire This form of fuel can easily cause a flashover that can lead to temperatures that are too high 7 Warranty Warning Use replacement parts recommended only...

Page 15: ...place or build new chimney with a larger cross section Possibly install a smoke suction device The chimney is too low and hence a poor draught Increase the height of the chimney and or install a chimn...

Page 16: ...person without Nordpeis Northstar Sp z o o written permission Nordpeis AS Gjellebekkstubben 11 N 3420 LIIERSKOGEN Norwey of 1 2 Sheet M Sobkowski 44 S 18F Wk ad S 18F S 18F 696330 03 11 2016 12 02 20...

Page 17: ...rewall Brennbart materiale Br ndbart materiale Br nnbart material Tulenarka materiaali Combustible material FIG 1 800 250cm2 20 150 800 150 700 mm 800 795 10 10 795 670 20 200 250cm2 700 mm 200 800 mm...

Page 18: ...Thermotte FIG 2 Operating control Door opening FIG 3 Montering Assembling D E C B A 18...

Page 19: ...Adjustment of legs FIG 4 17 mm 13 mm FIG 5 Rear smoke connection 4 mm 4 mm 19...

Page 20: ...FIG 6 Rear smoke connection FIG 7 Rear smoke connection A B C 5 mm 20...

Page 21: ...FIG 8 Thermotte assembling FIG 8a 1 2 Front cover assembling 21...

Page 22: ...FIG 9 Thermotte assembling 3 3 1 1 2 FIG 10 Thermotte assembling 22...

Page 23: ...FIG 11 Thermotte assembling FIG 12 Thermotte assembling 23...

Page 24: ...FIG 13 B 4 mm 24 PLASSERING AV SERIENUMMER POSITION OF THE SERIAL NUMBER...

Page 25: ...150mm 700 mm Emission of combustion Emissionswerte CO 0 07 vol NOx 98 mg m 3 OGC 51 mg m 3 PM Surface temperature Oberfl chentemperatur Pass Bestanden Machanical resistance Mechanischer Widerstand Pa...

Page 26: ...utput Useful efficiency NCV as received Nominal heat output Pnom 4 kW Useful efficiency at nominal heat output th nom 82 Auxiliary electricity consumption Type of heat output room temperature control...

Page 27: ...4 0 A A B C D E F G 2015 1186 kW ENERGIA ENERGIJA ENERGY ENERGIE A A A A A A Nordpeis AS Nordpeis S18 27...

Page 28: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...

Reviews: