1DWLRQDOUHTXLUHPHQWV)RUWKHÀXHFRQQHFWLRQWRWKH
chimney, follow the recommendations from the chimney
manufacturer.
Assembling Front Heat Shield FIG 7
1. Assemble front cover by bending its sides as shown
on the drawing FIG 7A & FIG 7B.
2. Place the radiation shield cover on its place as,
take care that slots at the end of cover matches to
hooks of rear cover - see FIG 7C
Multipurpose key
The insert is equipped with an handle, which is intended
for operating, ie.: air vents, opening and closing doors -
see FIG 8-FIG 8C.
Operational control
When the insert is in upright position, and
prior
to mounting the surround,
control that all functions
are easy to maneuver and appear satisfactory. See also
FIG 8a & FIG 8b
A. Ignition vent control
B. Air vent control
Pushed in = closed
Pull out = open
Left position = closed
Right position = open
Removing the self-closing door mechanism FIG 9
In order to deactivate - follow instruction below:
- open the door,
- lock the spring by fastening the screw - FIG 9A,
- lift the door up and unfasten the screw - FIG 9B, when
a noise could be heard the self-closing door is
deactivated,
- lower the door back to its place.
Painting the surround
It is recommended to use the insert a few times in order
to let the varnish harden before any eventual masking
and painting. Only use water based breathing paint and
a designated masking tape. Carefully remove the tape
in order not to damage the varnish.
/LJKWLQJD¿UHIRUWKH¿UVWWLPH
When the insert is assembled and all instructions have
EHHQREVHUYHGD¿UHFDQEHOLW
Take care when inserting logs into the burn chamber, in
order not to damage the Thermotte plates.
This will be resolved once the humidity has evaporated.
,IQHHGHGOHDYHWKHGRRUVOLJKWO\RSHQWKH¿UVWWLPHV
the insert is used.
FIG B
FIG A
It is advisable to ventilate the room well when using
IRUWKH¿UVWWLPHDVWKHYDUQLVKRQWKHSURGXFWPD\
release some smoke or smell
. Both the smoke and
smell will disappear and are not hazardous.
Kindling wood
Finely chopped (diameter of 3-5cm)
Length: 25-30cm
Ca. amount pr lighting : 2,1 kg (beech)
Place the air vent control in ignition (FIG A) (Pull out).
Insert small, dry pieces of wood, ignite and ensure the
ÀDPHVKDYHWDNHQSURSHUKROGRIWKHZRRG:KHQWKH
ÀDPHVDUHVWDEOHDQGWKHFKLPQH\LVZDUPSXVKLQWKH
DLUFRQWURORXWRIWKHLJQLWLRQPRGHDQGUHJXODWHWKH¿UH
normally.
When there is a glowing layer of ash, new wood logs
can be inserted. Pull the hot ember to the sides of the
combustion chamber when inserting new logs so that
the wood is ignited from the bottom. Insert 2 logs. One
positioned diagonally to the bottom with left end closer
to left front side of window pane. The second leaned
DJDLQVW¿UVWRQHDOVRGLDJRQDOO\LQRSSRVLWHGLUHFWLRQ
6HWWKHDLUYHQWRQDLUYDOYHRSHQLQJ7KH¿UH
VKRXOGEXUQZLWKEULJKWDQGOLYHO\ÀDPHV
Reload size
Chopped wood - 2 logs (diametre of 6-9cm)
Length: 25-30cm
Normal load size. 1,46 kg /h
(Max load size: 2,5 kg/h)
Attention!
8VLQJWKHLQVHUWZLWKORZFRPEXVWLRQHႇHFWDQG¿ULQJ
around the clock increase pollution as well as the risk
IRUD¿UHLQWKHFKLPQH\1HYHUDOORZWKHLQVHUWRUÀXHWR
EHFRPHJORZLQJUHG7XUQRႇWKHDLUYHQWFRQWUROVKRXOG
this happen. Regulation of the air vent control takes
some experience, but after a little while a natural rhythm
IRUWKH¿UHZLOOEHIRXQG
IMPORTANT! Always remember to open
the air vent control (preferably also the door)
before new wood logs are inserted into a hot burn
FKDPEHU/HWWKHÀDPHVJHWDJRRGJULSRQWKH
wood before the air control setting is reduced.
When the draught in the chimney is low and
WKHYHQWLVFORVHGWKHJDVIURPWKH¿UHZRRG
can be ignited with a bang. This can cause
damage to the product as well as the immediate
environment.
Warning!
In order to avoid injuries, please be aware that the
surfaface may become hot during operation and
extra care need to be taken to avoid skin burn.
WARNING:
Never leave the air control in ignition mode for pro-
longed periods as this may lead to overheating.
13
GB
Summary of Contents for IN-0N20U-011
Page 9: ...1 8 PP 5HYLVLRQ QRWH 1DPH 2XWVLHG GLPHQVLRQV RI WK UDZLQJ XSGDWH DIWHU FKDQJHV D 31...
Page 14: ...FIG 4b Torx 20 21 30011 408 x4 22 00N20 290 x4 FIG 4c 36...
Page 15: ...FIG 4d FIG 4e 37...
Page 16: ...FIG 5 Smoke adapter rear chimney connection FIG 4f 38...
Page 21: ...FIG 11 LA 0N20U 030 x1 FIG 12 22 0N20U 11L x1 22 0N20U 11R x1 43...
Page 22: ...FIG 14 LA 0N20U 020 x1 FIG 13 21 40005 516 x3 22 0N20U 130 x1 LA 0N20U 060 x2 3 0 mm 44...
Page 23: ...FIG 14b FIG 15 LA 0N20U 010 x1 45...
Page 24: ...FIG 15c FIG 15b 46...
Page 29: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...