1. Prior to assembling the insert
All our products are tested according to the latest
European requirements and also
to the Norwegian
standard NS 3058 and NS 3059,
which include particle
tests. However, several European countries have local
UHJXODWLRQVIRULQVWDOODWLRQRI¿UHSODFHVZKLFKFKDQJH
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
ZKHUHWKH¿UHSODFHLVLQVWDOOHG1RUGSHLV$6LVQRW
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive)
:
GLVWDQFHIURP¿UHER[WRFRPEXVWLEOHÀDPPDEOH
materials
• insulation materials/requirements between
¿UHSODFHVXUURXQGDQGEDFNZDOO
VL]HRIÀRRUSODWHVLQIURQWRI¿UHSODFHLIUHTXLUHG
ÀXHFRQQHFWLRQEHWZHHQ¿UHER[DQGFKLPQH\
LQVXODWLRQUHTXLUHPHQWVLIÀXHSDVVHVWKURXJKD
ÀDPPDEOHZDOO
DQDFFHVVIRUFOHDQLQJWKHDSSOLDQFHWKHÀXHJDV
FRQQHFWRUWKHFKLPQH\ÀXHPXVWEHSURYLGHG
Chimney draft
Compared with older models, the clean burning inserts
RIWRGD\SXWVLJQL¿FDQWO\KLJKHUGHPDQGVRQWKH
chimney. Even the best insert will not work properly
if the chimney does not have the right dimensions or
is not in good working order. The draught is mainly
controlled by gas temperature, outside temperature, air
supply as well as the height and inner diameter of the
chimney. The diameter of the chimney should never
EHOHVVWKDQWKDWRIWKHÀXHFKLPQH\FROODU)RUGUDIW
requirements at nominal heat output,
see technical
table
The draught increases when:
• The chimney becomes warmer than the outside air
• The active length of the chimney over the hearth
increases
• Good air supply to the combustion
,WFDQEHGLႈFXOWWRREWDLQWKHULJKWGUDXJKWFRQGLWLRQV
in case the chimney is too large relative to the insert,
as the chimney does not heat up well enough. In such
cases you may want to contact professional for
evaluation of possible measures. Draught that is too
strong can be controlled with a damper. If necessary,
contact a chimney sweeper.
$WWHQWLRQ$GYHUVHÀXHGUDXJKWRUDGYHUVHZHDWKHU
conditions, e. g. mist, wind etc., may interfere the
QHFHVVDU\ÀXHGUDXJKW7KLVVKRXOGEHFKHFNHGEH
-
IRUHOLJKWHQLQJWKH¿UHSODFH,IWKHUHLVQRQHFHVVDU\
ÀXHGUDXJKWLQWKHFKLPQH\WKHXVHRIWKH¿UHSODFH
should be avoided.
6KDUHGÀXHJDVV\VWHP
$SSOLDQFHFDQEHFRQQHFWHGWRVKDUHGÀXHJDVSLSH
sytem. In case of simultaneous operation with other
KHDWLQJDSSOLDQFHVWKHUHPXVWEHVXႈFLHQWFRPEXVWLRQ
air provided.
Air supply (mm=AIR)
A set for fresh air supply is available as an accessory.
This will ensure that the air supply to the combustion
FKDPEHULVOHVVDႇHFWHGE\YHQWLODWLRQV\VWHPVNLWFKHQ
fans and other factors which can create a down-draught
in the room. In all new constructions, we strongly
recommend the product is designed and prepared
for direct supply of outside air. In older houses also,
the use of fresh air supply set is also recommended.
,QVXႈFLHQWDLUVXSSO\FDQFDXVHSRRUGUDXJKWDQG
WKHUHE\ORZFRPEXVWLRQHႈFLHQF\DQGWKHSUREOHPVWKLV
HQWDLOVVRRWVWDLQVRQWKHJODVVLQHႈFLHQWXWLOLVDWLRQRI
the wood and a soot deposits in the chimney.
For your own safety, fully comply with the assembly
instructions. All safety distances are minimum distances.
Installation of the insert must comply with the current rules
and regulations of the country where the product is installed.
Nordpeis AS is not responsible for wrongly assembled inserts.
Subject to errors and changes.
For the latest updated version of the manual go to
www.nordpeis.com
2. Technical information
Inserts from Nordpeis all have secondary combustion
and are clean burning. The combustion takes place
LQWZRSKDVHV¿UVWWKHZRRGEXUQVDQGWKHQWKH
gases from the fumes are lit by the heated air. This
ensures that new inserts have minimal emissions of
soot particles and un-burnt gases (such as CO) and
are thus better for the environment. Clean burning
inserts require a small amount of wood to obtain good
heat output. Use exclusively clean and dry wood. We
recommend seasoned hardwood with a maximum
moisture content of 20%.
Warning! In case of the appliance connected to
VKDUHGÀXHJDVSLSHV\VWHPWKH6HOI&ORVLQJ
Door system must be operational.
Warrning! Extractor fans when operating
in the same room or space as the appliance
may cause problem.
Warning: Keep the air intakes, supplying
combustion and convection air free from blocka-
ge. If the requirements for ventilation are
NOT complied with, the product can overheat.
7KLVFDQFDXVHD¿UH
11
GB
Summary of Contents for IN-0N20U-011
Page 9: ...1 8 PP 5HYLVLRQ QRWH 1DPH 2XWVLHG GLPHQVLRQV RI WK UDZLQJ XSGDWH DIWHU FKDQJHV D 31...
Page 14: ...FIG 4b Torx 20 21 30011 408 x4 22 00N20 290 x4 FIG 4c 36...
Page 15: ...FIG 4d FIG 4e 37...
Page 16: ...FIG 5 Smoke adapter rear chimney connection FIG 4f 38...
Page 21: ...FIG 11 LA 0N20U 030 x1 FIG 12 22 0N20U 11L x1 22 0N20U 11R x1 43...
Page 22: ...FIG 14 LA 0N20U 020 x1 FIG 13 21 40005 516 x3 22 0N20U 130 x1 LA 0N20U 060 x2 3 0 mm 44...
Page 23: ...FIG 14b FIG 15 LA 0N20U 010 x1 45...
Page 24: ...FIG 15c FIG 15b 46...
Page 29: ...Nordpeis AS Gjellebekkstubben 11 N 3420 LIERSKOGEN Norway www nordpeis no...