19
The following checks should be carried out on a regular basis:
•
Inspect and clean the steam cylinder.
If there are any deposits in the steam cylinder, you should remove the
drainage strainer and flush the cylinder thoroughly with tap water
(using no chemical substances). If the electrodes are worn, it is time to
replace the steam cylinder.
• Inspect the steam and water hoses.
Check that they are still correctly laid and that the hose clamps are still
tight. Check that the hoses are still in good condition.
• Inspect and clean the inlet and outlet valves.
If worn, or covered in scale deposits, replace the valves.
• Check the drainage cup and, if necessary, clean or replace it.
5.6 Service program
The service program of the AT 3000 D steam-bath generators provides you
with information on operating conditions and allows you to check the
components. You are advised to check the components on a regular basis.
The service program is for interrogation and checking only. After you have
left the service program, the steam-bath generator works in accordance
with the operating conditions that were set originally.