let the air come in ,or use a fan to speed up air flowing so as to shorten the time needed for

defrosting .Never strike the frost layer with any iron tools or wood stick in order to avoid

damage to the evaporator tubing .

6) Refrigerating oil left in evaporator tubing

Analysis of Trouble

During the process of refrigerating cycles ,a little refrigerating oil may remain in the

evaporator tubing ,and after a longer time of operation ,if there is considerable refrigerating

oil left in the evaporator ,the heat conduction effect will be severely affected ,thus causing a

poor refrigerating effect .

Remedy

It is quite difficult to determine whether this trouble is caused by the refrigerating oil left in

the evaporator tubing ,because this kind of phenomenon and other several trouble are

tends to be confused .Generally speaking ,you can make a judgment based on the frost

formed on the evaporator .If the frost does not cover the evaporator , and moreover ,it is

loosely formed ,you can make a judgment that the deterioration of refrigerating effect is

due to the accumulation of refrigerating oil left in the evaporator tubing in case no other

troubles have been found . To clear off refrigerating oil left in the evaporator ,dismantle the

evaporator ,purge it thoroughly and then dry it .In case it is difficult to dismantle it ,charge

refrigerant from the evaporator inlet to wash it several times ,then purge and dry it with

nitrogen .

7) Flowing obstructed in refrigerating system

Analysis of Trouble

Because the refrigerating system was originally not purged thoroughly ,some of the filter

screen meshes have been clogged by dirt accumulated in the filter after using it for a

certain time of period ,thus resulting in a decrease in flow rate ,and hence a poorer

refrigerating effect . The abnormal phenomena caused by this kind of slight clogging in the

system are as follows: the gas discharge pressure is lower ,the temperature of discharged

gas drops down ,the position clogged has a temperature lower than that in normal

conditions ,and for a severe clogging ,even dew condensation as frosting may appear .

Remedy

Purge the tubing ,and after replacing the dry filter with a new one or clearing it

thoroughly ,recharge the system with refrigerant and seal the charging port .

B. No Refrigerating

The phenomenon that the compressor runs normally ,but no frost (or only a little frost )

appears on the evaporator ,and the refrigerator temperature does not drop down is called

"no refrigerating". There are many causes for this trouble and it is relatively complicated ,

too . In servicing ,special attention to finding direct causes for this phenomenon .Three

main potential causes for this trouble are analyzed below :

1) All refrigerant in the system has leaked out

Analysis of Trouble

Leak points in the refrigerating system have not been found and repaired timely ,thus

resulting in the total escape of refrigerant .There are two kinds of leakage :

I)

slow leakage

for instance ,when we want to use a refrigerator that has been put out of

quite a long time ,we find the leakage of refrigerant ,or in the course of its operation ,we

Summary of Contents for RD-110L

Page 1: ......

Page 2: ...uct code illumination and Series Introduction 2 3 Specifications 3 4 Safety precautions 4 5 Function Schedule 7 6 System Flow Chart 8 7 Circuit Diagram 9 8 Maintenance Service and Trouble Shooting 10 9 Exploded View 30 10 List of Parts 31 ...

Page 3: ... capacity L 110 Color White Power Supply V Hz 220 50 Rated Input Power W 77 Power Consumption kW h 24h 0 41 Net Weight kg 26 Gross Weight kg 29 Unit Dimension D W H mm 514 504 845 Packing Dimension D W H mm 560 540 885 Container Quantity 40 HQ PCS 264 ...

Page 4: ...l out the plug of the appliance by drawing the power cable Be sure to directly pull it of the outlet by firmly grasping the plug Do not move the appliance by pressing the power cable or tread on it When moving the appliance from wall be careful not to roll or damage power cable In case of damaged power cable If the power cable or plug was damaged it is prohibited to continue using it In this case ...

Page 5: ...ict requirement for temperature Do not store or use gasoline or other flammable article in the vicinity of the refrigerator to avoid fire Do not place any electrical plugs regulators or microwaves on top of the refrigerator Do not use electric appliances except those allowed by manufacturer in side the refrigerator Do not play by hanging on its door to prevent tilting the door or toppling the refr...

Page 6: ...ormance of the appliance It is strictly prohibited to privately dismantle or change the appliance component For the repair of refrigerator it can be carried out by professional only Do not put the bottled beer or beverage in the freezer compartment to prevent frost crack In case of unstable power supply or during cleaning it is required to pull out the power plug and to wait at least 5 minutes for...

Page 7: ......

Page 8: ...low Chart 1 Compressor 2 Condenser 3 Dry filter 4 Capillary tube 5 Evaporator 2 Brief Description of System Flow Chart Model BC 110A is a direct cooling single system refrigerator When the refrigerator is just powered on the refrigerant flows in the sequence 1 2 3 4 5 1 ...

Page 9: ...am 2 Brief Description of Control Principle Model BC 110A is a direct cooling single system larder A mechanical type of all the control is generally adopted The thermostat directly controls the start and stop of compressor and hence the refrigerator temperature ...

Page 10: ...nt true No cooling If compressor can run after it stop to run five minutes and give power Check and repair according to the section of the compressor does not work If compressor can run naturally and temperature raising of condenser is very Refrigerant leak Check repair and charge refrigerant again Block by ice or dirty things change filter and change refrigerant again ...

Page 11: ...ling Is cooling capacity insufficient Check and repair according to the section of Cooling capacity is insufficient 1 The thermostat was set at the coldest position 2 The ambient temperature is very high or the refrigerator is near by heat resource 3 The door was opened too many times or there is more fresh food inside Adjust and instruct consumer how to use Check and repair the main control panel...

Page 12: ...12 Maintenance Service and Trouble Shooting 3 Cooling capacity is insufficient YES NO YES YES NO YES Cooling capacity is insufficient Adjust and instruct consumer how to use Repair ...

Page 13: ...The compressor doesn t work YES NO NO YES YES NO YES YES NO YES NO YES The compressor doesn t work Is the interior light on when door is opened Is the power of 220V output Do the compressor have 220V output Check and repair compressor and accessory ...

Page 14: ......

Page 15: ...em and take reasonable remedy measures based on their comprehensive analysis of trouble characteristics as well as operating conditions for various kinds of refrigerators Three Essentials for Checkup 1 Look a Check the tubing of refrigerating system for cracks and various welding points for leaks if leakage occurs an oil stain can be seen definitely b Check the suction and exhaust pressure values ...

Page 16: ......

Page 17: ... the same ambient temperature Remedy In case there is leakage of refrigerant from the system do not hurry to recharge it with refrigerant manage to find out leak points immediately and make a note of from where it leaks welding points and parts After having them repaired recharge refrigerant There are so many joints and sealed There are so surfaces in a refrigerator accordingly quite a lot potenti...

Page 18: ... Analysis of Trouble Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharge capacity and hence the corresponding reduction of refrigerating capacity under the condition that the refrigerant in the system is unchanged This phenomenon occurs mostly when the compressor has been used for quite a long time its moving parts have worn to a considerable degree fit cle...

Page 19: ... in refrigerating system Analysis of Trouble Because the refrigerating system was originally not purged thoroughly some of the filter screen meshes have been clogged by dirt accumulated in the filter after using it for a certain time of period thus resulting in a decrease in flow rate and hence a poorer refrigerating effect The abnormal phenomena caused by this kind of slight clogging in the syste...

Page 20: ......

Page 21: ...ing of gas suction valve and discharge valve to suck and discharge the refrigerant If the valve block is broken the refrigerant can not be discharged and hence no refrigerating can be achieved Method for making judgment It is quite difficult to differentiate this trouble from others because they often have similar symptoms In repairing firstly hear attentively if there is some abnormal sound comin...

Page 22: ...s been left in the refrigerating system Generally there are two possibilities one is that the air has been sucked into the system when repairing due to carelessness or it has not been purged out totally when evacuating the system the other is that there are leak points at the low pressure end of the refrigerating system Leak points appear mostly in those low temperature parts or assemblies because...

Page 23: ...e compressor circuit Analysis of Trouble In case the compressor cannot be started this will generally exhibit in the power supply circuit for instance power failure poor contact of switch and blown fuse Make a comprehensive analysis of these phenomena fine out its real cause and take correct measures to remove this trouble Remedy a Check the input power circuit to see whether where is voltage of t...

Page 24: ... the fuse will be blown repeatedly and the blowout occurs particularly at the instant when you close the knife switch Remedy Check the terminals and the outer casing to see whether they are short circuited and measure the resistance of each phase with an ohmmeter If short circuit occurs or the resistance of a certain phase is low this means that short circuit does exist in the windings and or betw...

Page 25: ...her it is set in the position coldest 2 Thermostat is malfunctioning and makes the compressor running continuously Analysis of Trouble When the thermostat doesn t work normally it will make the compressor run continuously and hence very low temperature will be achieved in the refrigerator The fault is generally due to the fact that the contacts of the thermostat cannot be released Remedy Dismantle...

Page 26: ...ced as soon as you touch the metal parts of the refrigerator with your hand When you test them with a test pencil its neon lamp will come on In that case the first thing you need to do is to determine whether the grounding is perfect If the grounding is no problem turn off the refrigerator immediately then check the insulation of electric circuits with an multimeter b Serious electric leakage Neve...

Page 27: ...e vibration and noise 4 Inspection method To find the sources of noise press the vibration spot with your hand while the refrigerator is in operation and listen attentively whether the vibration becomes weake or vanishes If the refrigerator has not been levelly placed put a level meter on its top table and adjust the leveling screws on its legs In case noise occurs from the compressor strike diffe...

Reviews: