2
Reset to Factory Defaults
Reset active configuration to factory defaults is set by scanning Option
ZA
, followed
by scanning Option
HD
.
1.
ÉÁZA#Ë
2.
ÉÁHDoË
ZA
HD
Setting Symbology Parameters
The LM500 Plus module is able to decode UPC-A, UPC-E, EAN-8, EAN-13, Code 39, Code
128, Code 93, Codabar, Interleaved 2 of 5, and Standard 2 of 5 symbologies. The decoder
will actively attempt to match bar code data against all symbologies which are enabled.
Thus, performance is enhanced by disabling symbologies which are not used in a particular
environment.
The symbol * indicates default Parameters for normal mode
Enabling All Symbologies
It is possible to enable all symbologies at once. This command is typically used for diagnostic
or demonstration purposes. For best performance in actual use, only those symbologies which are
needed should be enabled.
QM
ÉÁQM5Ë
Enable all symbologies
EAN
RA
ÉÁRAzË
Disable EAN-13
RC
ÉÁRCÁË
*
Enable EAN-13
RN
ÉÁRN:Ë
Disable EAN-8
RP
ÉÁRP@Ë
*
Enable EAN-8