LEAK TEST
Testing Position
Testing Position
Testing
Position
Always perform a leak test in a well-ventilated area. Always wipe the mixed solution
(½ water and ½ liquid detergent / soap) from all connection after leak test.
1.
Confirm control knob is in the OFF position.
2.
Install the gas cartridge in position.
3.
Push the gas cartridge lock down. Turn on the gas.
4.
Check for leaks by brushing a solution of ½ water and ½ liquid detergent / soap over all the gas
system joints, including all valve connections, hose connections.
5.
NEVER USE AN OPEN FLAME to test for leaks at any time.
6.
If bubbles form over any of the joints there is a leak.
• Turn off the gas supply
• Re-tighten all joints
• Repeat test
If bubbles form again do not use the barbecue and contact your local Nordic Season™ distributor for
assistance.
1.
The gas cartridge should be placed safely away from any source of
heat or ignition, and never under direct sunlight. Store cartridge in a
cool and dry place where the temperature is less than 40°C.
2.
Store cartridge in a secure place.
3.
Do not subject the cartridge to impact or rough shake.
4.
Do not puncture or incinerate empty cartridge.
5.
Do not place cartridge in boot of a car or any unventilated location.
CAUTION Gas Cartridge
Placement of grill
●
Make sure that the grill has at least 40 cm distance in all directions from
house walls, trees, plants and other flammable materials / liquids.
●
The grill should not be placed under a roof or developer.
●
Make sure the grill is located in an area with good ventilation.