User Manual
User Manual
ENG
ENG
Control panel
1. Power: On/Off button. When the power is off during
the operation, the previous setting will resume when
it restarts.
2. Timer: press to set timing. When the timing symbol is
flashing, press up and down key to select the
required timing value. Timing values can be set in
1-24 hours
3. Down: press to decrease temperature and timing set value.
4. Mode: press to switch mode as cooling, fan,
dehumidifying modes.
5. Up: press to increase temperature and timing set value.
6. Fan: press to select high, low wind speeds. ·
Press “MODE” to select fan mode, High or Low Fan
speed.
7. Sleep Mode: Press to turn on the sleep mode. When
the sleep mode is turned on under cooling mode
on, the temperature will be increased by 1 °C every
hour and fan decrease to low speed. Sleeping mode
s invalid under dehumidifying, fan mode and when
water tank is full.
When the air conditioner is powered on for the first time,
and then the air conditioner will enter standby mode.
Protection modes
• Frost Protection:
In cooling or dehumidifying modes, if the temperature
of the exhaust pipe is too low, the air conditioner will
automatically enter protection status. When of the
exhaust pipe rises to a normal temperature, it will revert
automatically.
• Overflow Protection:
When water in the water tank exceeds the warning
level, the air conditioner will
automatically sound an alarm, and the "FULL" indicator
light will flash and should empty the water tank. (see
more details in Drainage Instructions)
• Protection Function of the Compressor
To increase the service life of the compressor, it has
a 3-minute delay booting protection function after the
compressor is turned off.
Installation
Warning:
before using the air conditioner, keep it
upright for at least two hours. The air conditioner can
be easily moved in the room. In the moving process,
ensure that the air conditioner is in the upright position
and it should be placed on a flat surface. Do not install
or use the air conditioner in the bathroom or other
humid environments.
Installation of assembled exhust pipe
Figure 1.
Insert assembled exhaust pipe (the end of the exhaust
joint) into the back-panel vent slot
(push to the left) and complete the assembly (as shown
in figure 1).
Installation of window sealing plate
components
1. Adjust their opening distance to bring both ends of
the assembly into contact with the window frame, and
fix various components of the assembly
2. Half open the window, and mount the window sealing
plate assembly to the window (as shown in Fig.2 and
Fig.3). Components can be placed in horizontal and
vertical direction.
Figure 2.
Figure 3.
3. The flat end of the exhaust pipe joints must be
snapped into place.
4. The distance between the body and walls or other
objects shall be at least 50 cm (as shown in Fig.4).
5. Elongate the exhaust pipe and snap the flat end of
the exhaust pipe joints into the hole of the
window sealing plate assembly (as shown in Fig.5
and Fig.6).
6. The pipe cannot be bent more than 45 degrees.
Figure 5.
Figure 6.
Important Notice:
The length of the exhaust hose shall be 280~1,500mm,
and this length is based on the specifications of
the air conditioner. Do not use extension tubes or
replace it with other different hoses, or this may cause
a malfunction. Exhaust host must be not blocked;
otherwise it may cause overheating.
Drainage Instructions
This air conditioner has two drainage methods: manual
drainage and continuous drainage.