![Nordcap 406600891 Service Manual Download Page 66](http://html1.mh-extra.com/html/nordcap/406600891/406600891_service-manual_1701373066.webp)
66
LIBERO LINE HOB INDUCTION
A
la
rm
c
ode
Invol
v
e
d
c
om
po
nent
P
owe
r
di
s
a
-
bl
e
S
e
lf
-re
s
e
t-
ti
ng
Alarm name
Alarm description
Alarm trou-
ble shoot-
ing
E701
E702
POW
Tesla
: Yes
Yes
Tesla:
BOARD_FAN_ER-
ROR
Tesla POW:
IGBT cooling fan blocked or not connected. Re-
marks:
•
The alarm is reset when the U.I. stay at least 120sec of
OFF
or
COOLING_DOWN
state, no matter if problem is
solved or not.
•
About 20 sec before the alarm occurs POW sent pot fail
state to the U.I.
Foucault HC:
One or more internal cooling fan blocked/not
connected/not following. Power disable depend on number of
fans blocked
Check cool-
ing fan of
POW
E711
E712
POW
Yes
Yes
EXTER-
NAL_FAN_ALARM
Tesla POW only:
External tangential fan blocked or not con-
nected.
Remarks: The alarm is reset when the U.I. stay at least
120sec of
OFF
or
COOLING_DOWN
state, no matter if prob-
lem is solved or not.
Check cool-
ing fan
E821
E822
U.I
Yes
Yes
POW_COMM_WD
OG_ALM
U.I1 detects POW1/POW2 communication timeout.
The alarm is showed on left display only (Both 821 and 822).
NOTE:
This alarm maybe generated by:
➢
A wrong MACS connection between U.I and POW
➢
A missing or wrong ID jumper on POW board.
With appliance with more than one POW (
e.g.
Double Zone
Fry top) it’s still possible to work with one zone only when the
other one is in error.
Check com-
munication
cables POW
to U.I.
E831
E832
U.I
Yes
Yes
MACS_ACK_TOUT
U.I1 detects MACS acknowledgements missing to POW1.
This alarm appears if communication is lost during standard
operation. The alarm is overridden by E821 after some sec-
onds. The alarm is showed on both display.
Check com-
munication
cables POW
to U.I.
E911
U.I
BUTTON _LOW
_REF
Touch button failure
Check U.I.
E921
U.I
BUTTON _LOW
_SIGNAL
Touch button failure
Check U.I.
E931
U.I
BUTTON _HIGH
_REF
Touch button failure
Check U.I.
E941
U.I
BUTTON _HIGH
_SIGNAL
Touch button failure
Check U.I.
E981
U.I
BUTTON_ERROR -
Init
Touch button failure
Check U.I.
E991
U.I
BUTTON_ERROR
– Run time
Touch button failure
Check U.I.
E9A1
U.I
BUTTON_ERROR
– FMEA Library
Touch button failure
Check U.I.
E9b1
U.I
BUTTON_ERROR
– FMEA short
Touch button failure, the alarm is showed on both display.
Check U.I.
E9C1
U.I
BUTTON_ERROR
– FMEA open
Touch button failure, the alarm is showed on both display.
Check U.I.
4.8 SOFTWARE UPDATE & WIFI
The software update is not possible on the electronic boards. WIFI is not implemented at this moment.
NOTE !
If the filters start t
o get dirty and limit the fresh air passage, before emitting an “over heating alarm E421” the
appliance will start to
limit the energy emission of the POW, a typical call from a customer could be “ the appliance
is not performing any more” or “ after some time the appliance is not performing”.
Summary of Contents for 406600891
Page 1: ...Service Manual Hob Induction Top IHEC 1P 2ZLT Art 406600891 2021 04...
Page 15: ...15 LIBERO LINE HOB INDUCTION 1PH SZ DZ DI...
Page 16: ...16 LIBERO LINE HOB INDUCTION 3PH SZ SA...
Page 17: ...17 LIBERO LINE HOB INDUCTION 3PH SZ DI...
Page 51: ...51 LIBERO LINE HOB INDUCTION...
Page 52: ...52 LIBERO LINE HOB INDUCTION...
Page 54: ...54 LIBERO LINE HOB INDUCTION...
Page 55: ...55 LIBERO LINE HOB INDUCTION...
Page 57: ...57 LIBERO LINE HOB INDUCTION...
Page 58: ...58 LIBERO LINE HOB INDUCTION...
Page 60: ...60 LIBERO LINE HOB INDUCTION...
Page 63: ...63 LIBERO LINE HOB INDUCTION NOTE E1 21 IS AN INVENTED ALARM JUST FOR ILLUSTRATION PURPOSE...
Page 69: ...69 LIBERO LINE HOB INDUCTION APPLIANCE CASING...