LIBERO LINE WOK INDUCTION 

  

4.8  ELECTRONIC BOARD 

  SWITCHING

 

ON

 

/

 

OFF 

Turn ON

 the appliance by pressing the On/Off button for 3 seconds. 

 
Once in 

ON

 state, there are different possibilities to return to 

OFF

 state again: 

 

Manual Switch OFF

, operating on the On/Off button. This possibility is always available, no matter if cooking 

zones are cooking or not. 

Automatic Switch OFF,

 when all cooking zones are not cooking, and the UI does not sense any user activity 

on the appliance for a proper timeout. 

Safety Switch OFF, 

when the UI sense a permanent pressure on at least one active button or slider point. 

 
 
 
 

 

 

 

NOTE ! 

When turning off in case of residual heat inside the cooking surface on the display will be visualized 

 

Summary of Contents for 1PH - WOK - DI

Page 1: ...Service Manual Wok Induction IWOKEC 3P 1ZT Art 406600897 2021 04 ...

Page 2: ...e still doubts regarding machine use do not hesitate to contact the Man ufacturer or the Customer Care to receive prompt and precise assistance for better operation and maximum efficiency of the machine During all stages of machine assessment always respect the current regulations on safety work hygiene and environmental protection It is the user s responsibility to make sure the machine is starte...

Page 3: ... 50 60 220 240 V 1N 3 600881 1PH WOK SA LLWS1S 50 60 220 240 V 1N 3 5 600893 1PH WOK SA LLWS1S 50 60 220 240 V 1N 3 5 600905 1PH WOK SA LLWS1S 50 60 220 240 V 1N 3 600884 3PH WOK DI LLWS3D 50 60 380 415 V 3N 5 600896 3PH WOK DI LLWS3D 50 60 380 415 V 3N 5 600885 3PH WOK SA LLWS3S 50 60 380 415 V 3N 5 600897 3PH WOK SA LLWS3S 50 60 380 415 V 3N 5 MODEL 1PH 3PH Phase SZ Single Zone DZ Double Zone SA...

Page 4: ... INSTALLATION SOLUTIONS 19 2 1 4 1 ON BASE REFRIGERATED BASE 19 2 1 4 2 ON LIBERO POINT 19 2 1 4 3 DROP IN 20 2 1 4 3 1 DIMENSIONS AIR REQUIREMENTS 21 APPLIANCE REQUIREMENTS 22 2 1 5 1 POWER VOLTS 22 2 1 5 2 AIR CIRCULATION 22 2 1 5 3 APPLIANCE LOAD 22 2 2 ELECTRIC CONNECTION 23 HOW TO RECOGNIZE PHASE AND NEUTRAL 24 RESIDUAL CURRENT 24 2 4 FIRST START UP 25 DAILY STARTUP 25 2 5 COMMISSIONING 25 3 ...

Page 5: ...TORY 43 SERVICE MENU 44 4 8 3 1 DEMO MODE 46 4 8 3 2 SI SOFTWARE EDITION 47 4 8 3 3 S2 SELF DIAGNOSTIC TEST OF GENERATORS OFF 49 4 8 3 4 S3 SELF DIAGNOSTIC TEST WITH GENERATORS ON 52 4 8 3 5 S4 COOKING TOP COUPLING 55 HOB TO HOOD H2H SPECIAL FUNCTION 58 MANUAL FAN SPEED 58 AUTOMATIC FAN SPEED 59 ALARMS 61 4 8 7 1 ALARM CODE LIST 63 4 9 SOFTWARE UPDATE WIFI 65 5 TROUBLESHOOTING 66 5 1 ALARM TROUBLE...

Page 6: ...6 LIBERO LINE WOK INDUCTION COMPONENTS APPLIANCE 5000W 72 6 2 3 1 GENERATOR FOUCAULT 73 6 2 3 2 AIR FILTERS 74 6 2 3 3 USER BOARD 74 ...

Page 7: ...ppliance Clarifications and explanations Only specialized personnel are authorized to operate on the machine This appliance must not be used by minors and adults with limited physical sensory or mental abilities or without adequate experience and knowledge regarding its use Do not let children play with the appliance Keep all packaging and detergents away from children Cleaning and user maintenanc...

Page 8: ...ns To guarantee machine efficiency and correct operation periodical maintenance must be carried out according to the instructions given in this manual Make sure to periodically check correct operation of all the safety devices and the insulation of electrical cables which must be replaced if damaged Extraordinary machine maintenance operations must only be carried out by specialized Technicians pr...

Page 9: ...the model 2 During these operations the worn gloves must be cut resistant Failure to use the personal pro tection equipment by operators specialized personnel or users can involve exposure to damage to health depending on the model GENERAL INFORMATION The machines are provided with electric and or mechanical safety devices for protecting workers and the machine itself Therefore the user must not r...

Page 10: ...ng the personal protection equipment to be used by them Sufficient spaces are provided for during the machine installation stages in order to limit these risks To preserve these conditions the areas around the machine must always be kept free of obstacles e g ladders tools containers boxes etc clean and dry well lit For the Customer s complete information the residual risks remaining on the machin...

Page 11: ...able materials in the vicinity of the appliance Install the appliance in a well ventilated place to avoid the creation of dangerous mixtures of unburnt gases in the same room Danger Meaning danger of burns danger of electrocution shown on electrical parts with indication of voltage risk of electromagnetic fields Access forbidden to wearers of electrical stimulator pacemakers End of use When the ap...

Page 12: ...n sticker is located on the bottom of the appliance The meaning of the various information is listed below EXAMPLE PICTURE SERIAL NUMBER PRODUCTION DATE is necessary to find the correct spare part or to ask tech support EXAMPLE Serial Number 1 14 2 0001 PNC SER EXAMPLE TYPE LL FT S 1 S ...

Page 13: ...one Power supply voltage V 220 240 380 415 Frequency Hz 50 60 50 60 Phases Nr 1N 3 Induction Wok Type LLWS1S LLWS1D LLWS3S LLWS3D Appliance description Single Zone Single Zone UK Single Zone Max current A 16 13 7 Max total power kW 3 5 3 5 Plug Type F Schuko G 3N PE 16A IEC 60309 TYPE LL Libero Line W Wok S Single zone 1 3 Phase S D Stand Alone Drop In ...

Page 14: ...14 LIBERO LINE WOK INDUCTION 1 5 OVERALL DRAWINGS WITH MEASUREMENTS 1PH 3PH Phase SZ Single Zone DZ Double Zone SA Stand Alone DI Drop In 1PH WOK SA 1PH WOK DI ...

Page 15: ...15 LIBERO LINE WOK INDUCTION 3P WOK SA 3PH SZ DI ...

Page 16: ...ccur and the zone will then be ready for temp regulation setting LOCK It is possible to lock the control panel while the cookingzones are in operation in order to prevent accidental changes of the power level To activate the function press the button for three seconds the corre sponding indicator turn red and blinks To deactivate the function touch the button again the previously set power level l...

Page 17: ... Interface HUI Hob User Interface ROADRUNNER User Interface PD or HPD Hob Pot Detection A circuit normally embedded in a POW able to detect pot presence over a coil HOB Induction Hob cooking appliance WOK Induction WOK cooking appliance FRY Induction Fry Top cooking appliance SZ Single Zone cooking appliance DZ Double Zone cooking appliance SA Stand Alone DI Drop In 1PH Single phase power supply l...

Page 18: ...m temperature range must be between 5 C and 40 C Outdoor functioning is strictly allowed only if the machine can be protected against any conditions being out of the above temperature range and against any atmospheric agents On a hot cupboard base take precaution to install a baffle for preventing hot air to reach the oven fresh air intake this could create malfunctioning High room humidity may ca...

Page 19: ...ST OF POSSIBLE INSTALLATION SOLUTIONS Hereinafter the instructions for the main installation possibilities The different accessories have a dedicated Installation Manual please refer also to these documents provided with the accessories or available on PRIDE 2 1 4 1 ON BASE REFRIGERATED BASE All Stand alone appliances can be fixed onto bases 2 1 4 2 ON LIBERO POINT The Stand alone appliances can b...

Page 20: ... it could complicate any future extraction 2 The fixing assembly can be inserted into the three different precut slots 1 2 3 depending on the thickness of the top 3 Fixing assembly installed 4 Tighten the screw to blocking the appliance into place 5 End result Pictures are examples for installation purposes NOTE The sponge gasket fixing assembly and air conveyor are not supplied with the drop in a...

Page 21: ... Operating Manual of this accessory for further installation instructions All documents are available for authorized technicians on the web sites PRIDE SERVICE PORTAL AGELUX etc In case of any doubt refer to your local country customer care Here is an example image of the conveyor installed NOTE The sponge gasket fixing assembly and air conveyor are not supplied with the drop in appliance they are...

Page 22: ... the appliances with a total weight of 40kg distributed across the surface in pots suitable for induction use and of a max diameter of 28cm EXAMPLE Let s do some considerations for a cooking zone For example a standard pot used in professional cooking would be a pot of 30cm diameter so the bottom would be approx 28cm and if it was 25cm high it would contain approx 18 liters of water add like 2kg f...

Page 23: ...pen position during maintenance Connect the appliance to an efficient earthing system Include also the appliance into an equipotential system The equipotential terminal block is located under the appliance and is marked WARNING Take GREAT CARE when connecting testing anything with live current if you are unsure what you are doing and how to use your equipment safely then DON T DO IT IMPORTANT The ...

Page 24: ...the readings should be L1 L2 L3 N Phase and Neutral 230 Volts 6 based on European standards L1 L2 L3 Phase and Earth 230 Volts L1 and or L2 L3 Phase and Phase 400 Volts N Neutral and Earth 0 Volts or approx zero V The combination and results obtained will permit you to find all wires PHASE NEUTRAL and EARTH RESIDUAL CURRENT The contact opening max distance and leakage current must comply with the ...

Page 25: ...ng DAILY STARTUP Please refer to the user manual the document is available for authorized technicians on the web sites PRIDE SERVICE PORTAL AGELUX etc In case of any doubt refer to your local country customer care Before you turn on the appliance make sure that The mains voltage and frequency match those indicated on the appliance data plate at DATA PLATE IDEN TIFICATION STICKER Visual check if th...

Page 26: ...nd Operating Manual of the appliance the document is available for authorized technicians on the web sites PRIDE SERVICE PORTAL AGELUX etc In case of any doubt refer to your local country customer care To use the appliance press the On Off button appliance will lamp test and go into idle Then deactivate a zone ...

Page 27: ... satin finish and rinse often rubbing in a circular motion combined with the particles of dirt on the cloth sponge could damage the steel s satin finish Dry carefully the surfaces after cleaning AIR FILTERS The air filters can be washed separately or inserted into a dish washing machine dry carefully or leave to dry on a dish rack or towel The air filters need to be cleaned when dirty it s not nec...

Page 28: ...igh performer and will require a big amount of fresh air to cool its internal components In case that the air filters do not get cleaned when dirty the appliance could overheat and an alarm will be shown on the display WARNING Take GREAT CARE when connecting testing anything with live current if you are unsure what you are doing and how to use your equipment safely then DON T DO IT NOTE If the fil...

Page 29: ...00W GENERATOR TESLA POW The Tesla generator is used on the 1ph appliances Pos Component B1 Generator POB TESLA GENERATOR B2 Ventilator VENTILATOR B3 AIR Filters FILTER B4 Ventilator tang M1 VENTILATOR TANGENTIAL B5 User board USER INTER FACE U I B6 Coils tem perature sen sors COIL ...

Page 30: ... The ventilator BF001 is included into the Generator assembly it is not available as a single spare part The ventilator is commanded directly by the Generator its purpose is to cool down the heat dispel finned pack it s a 12v supplied motor ...

Page 31: ...BF002 is the tachometer signal cable NOTE If the filters start to get dirty and limit the fresh air passage before emitting an over heating alarm the appliance will start to limit the energy emission of the POW a typical call from a customer could be the appliance is not performing any more or after some time the appliance is not performing first phone check is making the customer have a look at t...

Page 32: ...munication cable U I to Generator To give power supply to the U I only one POW pob needs to have the bridge cable from BC001 to BC005 The POW that will not have connected a U I does NOT need this small bridge cable or the POW will go in short Refer also to the EWD at ELECTRIC WIRING DIAGRAM EXAMPLE ...

Page 33: ...212 the safety sensor will slowly cut down the power of the generator if the temperature of the surface does not go down and it reaches 222C the sensor will input to shut down the Generator There is no manual resetting of the safety sensor this be cause it is electronically controlled once that the appliance has cooled down the appliance will keep in function the ven tilation system in case of saf...

Page 34: ...on the side of the generator Pos Component C1 C2 Coils tempera ture sensors Generator POW FOUCAULT Filter GENERATOR FOUCAULT C3 User board U I USER BOARD U I Example of software set ted by the factory To check if the inner voltage adaptor is functioning The voltage adaptor is a component located inside the generator and cannot be replaced but It can be checked Locate the connectors check the indic...

Page 35: ... also to the EWD at ELECTRIC WIRING DI AGRAM EXAMPLE 4 6 INDUCTION POTS PRECAUTIONS All wok pans must be designed to be used on induction appliances generally all are branded with the indicated logo on the bottom Use pans with rounded bottom in iron iron plate enam eled iron cast iron special multilayer metal Do not use pots in layered metal with aluminum body and open edge The heating system will...

Page 36: ... it will not In the picture 1 is an example of the power absorbed by a bad pan and a good performing pan both pans are suitable for induction appliances but one pan is responding better To check the performance of pans there are TWO methods checking the power absorbed AMPS on each generator with a current clamp regulate the zone at full power measure and swap pans on the same zone remember that th...

Page 37: ...37 LIBERO LINE WOK INDUCTION POWER TABLE 1PH WOK Single Phase WOK POWER TABLE 3PH WOK 3 phase WOK ...

Page 38: ...On Off button This possibility is always available no matter if cooking zones are cooking or not Automatic Switch OFF when all cooking zones are not cooking and the UI does not sense any user activity on the appliance for a proper timeout Safety Switch OFF when the UI sense a permanent pressure on at least one active button or slider point NOTE When turning off in case of residual heat inside the ...

Page 39: ...n the meantime the UI switch ON as per standard way A first BEEP is generated A second BEEP is generated after 3 sec Key Lock and Service keys light ON white as in picture All other LEDs and keys are off and inactive BEEP OR OR UI is in COOLING_DOWN state and no HUI related alarms active TO BE CONTINUED User keep pressed Key Lock button for 3 sec until a third BEEP is heard 0 1 2 3 4 5 6 7 8 9 10 ...

Page 40: ...tory Hob2Hood mode Beep mode 8 sec 500ms ON OFF key OR Manual switch OFF Timeout event EXIT CUSTOMER MENU User touch the On Off key OR No active keys are touched within a 8 sec timeout UI return to OFF or COOLING_DOWN state Beep mode BEEP BEEP 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1 ...

Page 41: ...ressure on the key cyclically change the Beep mode The user enter the CUSTOMER Example only current Beep mode maybe b0 or b1 Beep mode b0 Full buzzer use Example only BEEP BEEP Once selected the desired Beep mode user can press key to switch to Hob2Hood setting page press On Off key to exit CUSTOMER MENU or wait 8 sec to automatically exit from CUSTOMER MENU Exiting the Beep Mode page the new mode...

Page 42: ... mode maybe from H0 to H6 Hob2Hood mode H5 Example only Hob2Hood mode H6 Hob2Hood mode H0 Hob2Hood mode H1 BEEP BEEP Hob2Hood mode H2 Hob2Hood mode H3 Hob2Hood mode H4 Hob2Hood mode H5 BEEP BEEP BEEP BEEP BEEP 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7...

Page 43: ... is completely off for void positions until the final timeout is reached At the end of the sequence the UI automatically return to the Alarm History initial page Alarm History initial page BEEP User can press key to switch to Beep mode setting page press key to restart alarm history visualization press On Off key to exit CUSTOMER MENU or wait 8 sec to automatically exit from CUSTOMER MENU 0 1 2 3 ...

Page 44: ...second BEEP is generated after 3 sec Key Lock and Service keys light ON white as in picture All other LEDs and keys are off and inactive BEEP UI is in COOLING_DOWN state and no HUI related alarms active OR 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 60 200 280 0 60 200 280 C C 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 60 200 280...

Page 45: ...utility S1 Service utility S2 Demo mode BEEP BEEP Service utility S3 Service utility S4 BEEP Demo mode d or do TO BE CONTINUED 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10...

Page 46: ...h OFF Timeout event EXIT SERVICE MENU User touch the On Off key OR No active keys are touched within a 8 sec timeout UI return to OFF OR OR COOLING_DOWN state BEEP BEEP 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 60 200 280 0 60 200 280 C C 4 8 3 1 DEMO MODE ...

Page 47: ...digit shows the last two numbers of HUI software version Step 1 Example for SW Ver 44 3 sec HUI software version STEP 2 CONFIGURATION VERSION Left digit shows step indication 2 Right digit shows the last two numbers of configuration version Step 2 Example for configuration 87 3 sec Configuration version TO BE CONTINUED 0 1 2 3 4 5 6 7 8 9 10 0 1 2 3 4 5 6 7 8 9 10 0 60 200 280 0 60 200 280 C C 0 1...

Page 48: ...it from SERVICE MENU NOTE Described sequence can be interrupted anytime pressing the On Off key The HUI will automatically return to OFF or COOLING_DOWN state All other keys are disabled HC1 Power Micro version Example for Power Micro version not present 3 sec 3 sec 3 sec HC2 Power Micro version STEP 6 HC2 POWER BOARD Power Micro VERSION Tesla HC Not used right digit shows Foucault HC Right digit ...

Page 49: ...ENERATORS OFF Service Utility S2 Power boards POW self diagnostic test with induction generators OFF During this test there is no need to place pots on cooking zones Induction generators are OFF APD relay open so meaning pot detection and power generation is not done ...

Page 50: ...50 LIBERO LINE WOK INDUCTION ...

Page 51: ...51 LIBERO LINE WOK INDUCTION ...

Page 52: ...ors meaning all coils on all cooking zones are ON at maximum power defined in the configuration Level 9 NOTE This test is not always accurate By repeating the test several times it happens with a certain frequency that the equipment is unable to provide the result without a physical change having occurred on the equipment On double zone appliances most of the time only the result of POW1 Zone 1 le...

Page 53: ...53 LIBERO LINE WOK INDUCTION ...

Page 54: ...54 LIBERO LINE WOK INDUCTION ...

Page 55: ...st A quick explanation of how this test works The test is done in three steps Step 1 The POW measures the main power supply voltage without load zero power request Step 2 The maximum power equivalent to level 10 is requested to the cooking area under test Real generated power is estimated measuring the current on the coil and a coupling factor is showed as Coupling factor Estimated power Requested...

Page 56: ...56 LIBERO LINE WOK INDUCTION ...

Page 57: ...57 LIBERO LINE WOK INDUCTION ...

Page 58: ...bility to select desired hood fan speed from speed zero meaning fan OFF to speed 4 max by repeatedly pressing the H2H button on the U I of the appliance This function is always available when the UI is ON no matter if cooking zones are IDLE STANDBY or COOKING sub state When U I enters an ON state the manual Fan Speed is not active Fan speed is initially set to zero and will eventually change depen...

Page 59: ...d for Automatic Fan Speed but just for Manual Fan Speed regulation Automatic fan speed signals are sent also during Cleaning or even if there is an POW error Required speed maybe wrong when the error involves a temperature sensor because temperature reading is unreal H2H ICON Regardless of whether Manual or Automatic Fan Speed mode is active H2H icon indicated the required hood fan speed as follow...

Page 60: ...60 LIBERO LINE WOK INDUCTION ...

Page 61: ...rror appears on the U I zone associated to the gener ator in error or unable to work as a consequence of the malfunction So meaning In one display only when the alarm impact only one generator inside a specific POW e g E411 Coil temperature sensor open not connected Visualization is done on the U I zone associated to the defective generator This is done to allow technician to correctly identify th...

Page 62: ...62 LIBERO LINE WOK INDUCTION NOTE E1 21 IS AN INVENTED ALARM JUST FOR ILLUSTRATION PURPOSE ...

Page 63: ...ad circuit means temperature 290 C on Tesla POW Bad circuit means temperature 300 C on Foucault POW For Tesla POW HOB WOK diagnostic is executed on both generators Front and Rear even if not really used in a spe cific configuration i e in a single zone configuration For this reason a dummy sensor 100kOhm resistance must be con nected on the unused input Check temp sensors E411 E412 POW Yes Yes TEM...

Page 64: ...Front and Rear within the single Tesla POW S3 SELF DIAGNOSTIC TEST WITH GENERATORS ON Check temp sensors DUMMY sensor has been swapped position af ter Spare Part re placement E501 U I No No The alarm is showed on both display left and right On Libero Line this may happen when a wrong firmware is used for the hardware Check cor rect U I spare part E601 POW No Yes 15V BAD 15 Volt supply out of windo...

Page 65: ... zone only when the other one is in error Check com munication cables POW to U I E831 E832 U I Yes Yes MACS_ACK_TOUT U I1 detects MACS acknowledgements missing to POW1 This alarm appears if communication is lost during standard operation The alarm is overridden by E821 after some sec onds The alarm is showed on both display Check com munication cables POW to U I E911 U I BUTTON _LOW _REF Touch but...

Page 66: ...EDED TOOLS Complete Socket Wrench set from 6 to 24 Complete allen key set Bent long nose pliers Screwdrivers Philips small medium large Screwdrivers flat small medium large Clamp amp meter Multimeter voltage reader Tongue groove pliers water gas pipes Grip lock plier Protective gloves heatproof cut proof Refer also to the PERSONAL PROTECTION EQUIPMENT WARNING Take GREAT CARE when connecting testin...

Page 67: ...ide to access various parts To locate the component of interest please refer to the following and illustrations Each component is marked with a name number and a page which explains in detail how to take it apart WARNING CAUTION Before any operation on the machine read Chapter SAFETY INFORMATION PRECAU TIONS We recommend for any phase involv ing the removal of the components to use cut resistant g...

Page 68: ...68 LIBERO LINE WOK INDUCTION APPLIANCE CASING ...

Page 69: ...TESLA Remove the appliance casing APPLIANCE CASING then Pos Component B1 Generator POB TESLA GENERATOR POB TESLA B2 Ventilator VENTILATOR B3 AIR Filters AIR FILTERS B4 Ventilator tang M1 USER INTER FACE U I VENTILATOR TANGENTIAL B5 User board B6 Coils tem perature sen sors COILS ...

Page 70: ...liance casing APPLIANCE CASING then 6 2 2 3 AIR FILTERS The air filters can be washed separately or inserted into a dish washing machine dry carefully or leave to dry on a dish rack or towel In case of clogging up the appliance can over heat and generate an alarm ...

Page 71: ...71 LIBERO LINE WOK INDUCTION 6 2 2 4 USER INTERFACE U I VENTILATOR TANGENTIAL Remove the appliance casing APPLIANCE CASING then The U I is fixed onto springs into slots in the paneling ...

Page 72: ... then the coils can be removed with their supporting paneling The coil assembly is fixed to the paneling with springs and slots on the supporting panel COMPONENTS APPLIANCE 5000W Pos Component C1 Generator POB FOUCAULT GENERATOR FOUCAULT B3 Air Filter AIR FILTERS B5 User board USER BOARD ...

Page 73: ...73 LIBERO LINE WOK INDUCTION 6 2 3 1 GENERATOR FOUCAULT Remove the appliance casing APPLIANCE CASING then NOTE The coil and temperature probe cannot be dismantled or as separate spare parts ...

Page 74: ...dish washing machine dry carefully or leave to dry on a dish rack or towel In case of clogging up the appliance can over heat and generate an alarm 6 2 3 3 USER BOARD Remove the appliance casing APPLIANCE CASING then disconnect the supply communication cables and lift the UI fix with slots onto the paneling s ...

Page 75: ... 28307 Bremen Hauptsitz Service Finanzen Personal Lager IT Marketing Telefon 49 421 48557 0 Telefax 49 421 488650 E Mail bremen nordcap de Die NordCap Verkaufsniederlassungen in Deutschland Nord Hamburg Ost Berlin Süd Ingelheim West Erkrath ...

Reviews: