3.1.8 Repairs
Repairs must be carried out by Getriebebau NORD or by an officially recognised expert. The work must
be indicated with an additional repair plate. With the exception of standard, commercially available and
equivalent components, only original spare parts (see spare parts list) may be used. The particularly
applies for seals and connecting components.
For motors with closed condensation outlets, the threads of the closing screws must be coated with
Loctite 242 or Loxeal 82-21 after the condensation has been drained. The closing screws must be re-
inserted immediately. The electrical connections must be checked at regular intervals.
Check that the connection terminals, and the electrical bonding terminal are firmly fastened. Check that
the cable gland and the terminal box gasket are in good condition
All work on electrical machinery must be performed when the machine is at a standstill and with all poles
disconnected from the mains.
The motor must be removed for any measurement of the insulation resistance. The measurement must
not be performed in the explosion hazard area. As soon as measurement has been completed,
discharge the connecting terminals again immediately by shorting them in order to prevent any spark
discharges occurring in the explosive area.
Pos: 75 /Anl eitungen/M otoren/B1091 Drehstromm otoren/Sicher heitshi nweise/GEF AHR _AT EX - Isolationsm essung - M otoren [B1091] @ 11\mod_1460013200941_388.docx @ 316406 @ @ 1
DANGER!
Explosion hazard
Insulation measurements may cause sparks and therefore ignition of an explosive
atmosphere.
• Only perform insulation measurements outside of an explosive atmosphere.
• Discharge the connection terminals by short circuiting them after the measurement and
before returning to an explosive atmosphere.
Pos: 76 /Anl eitungen/M otoren/B1091 Drehstromm otoren/3. AT EX/Lacki erung [EXE, EXN, Z one21+ 22] @ 67\mod_1613486826666_388.docx @ 2738934 @ 3 @ 1
3.1.9 Painting
The motors are equipped with a suitable, electrostatically tested painting ex-works. Subsequent painting
may only be carried out in consultation with Getriebebau NORD or a repair workshop approved for the
repair of explosion-protected electric motors. The valid standards and regulations must be observed.
Pos: 77 /Allgem ein/Allgem eing ültige M odul e/---------- Seitenum bruch ---------- @ 1\m od_1329145698658_0.docx @ 15891 @ @ 1
Summary of Contents for 6051302
Page 1: ...B 1091 en Motors Operating and Assembly Instructions...
Page 6: ...Motors Operating and Assembly Instructions 6 B 1091 en 2722...
Page 66: ...Motors Operating and Assembly Instructions 66 B 1091 en 2722 5 Declarations of Conformity...
Page 67: ...Table of Contents B 1091 en 2722 67...
Page 68: ...Motors Operating and Assembly Instructions 68 B 1091 en 2722...
Page 71: ...Table of Contents B 1091 en 2722 71 Ende der Liste f r Textm arke Inhalt...
Page 72: ...6051302 2722...