2. If this condition occurs only at high speeds, then a
transducer adjustment is needed. Refer to the
Transducer Installation Instructions for adjustment
procedure.
3. Check the transducer cable connection to the trans-
mitter. Make sure that the connection is made as per
the instructions in the Transducer Wiring Section of
this manual.
The Bottom Reading is Random, Flashing, or Appears
as “---” on the display.
1. The depth is less than 2.5 feet or greater than 200 feet.
Operate the unit under normal operating specifica-
tions and check to see if it operating properly.
2. If this condition occurs only at high speeds, then a
transducer adjustment is needed. Refer to the
Transducer Installation Instructions for adjustment
procedure.
3. Under certain circumstances the ML100 Series may
not perform at the best of its ability. Extremely dirty
water, very soft bottom, high speeds, deep water, or a
combination of the above will result in incomplete or
inaccurate readings. Please refer to the Transducer
Installation Instructions to minimize the effects of
these conditions.
4. Check the transducer cable connection on the trans-
mitter. Make sure that the connection is made as per
the instructions in the Transducer Wiring Section of
this manual.
26
The In-Dash Wireless Display (ML100DR) can also be
s u rface mounted using NorCro s s ’s exclusive MB01
Adjustable Surface Mount Bracket (see Figure 6). Please
see your local retailer, or contact NorCross by phone
888-NorCross, or online at:
www.norcrossmarine.com for purchase information.