58
www.norcold.com
Polar Series N7V, N7X, N7XL / N8V, N8X, N8XL
Fan and Cold Weather Heater
Fig. 20 - Fan and cold weather heater wiring
A
Fan / Bracket Assembly
B
Fan Thermostat
C
Condenser
D
Auxiliary Wire Harness
E
Cold Weather Heater
F
Cooling Unit
G
P1-1 Auxiliary 12 VDC (ground)
H
P1-6 Auxiliary 12 VDC (positive)
Ice Maker Only
Fig. 21 - Ice maker only wiring
A
Water Valve
B
Water Valve / IM Water Line Heater
C
Water Valve / IM Water Line Heater Thermostat
D
White from Power Cord
E
Brown from Ice Maker
F
P1-1 Auxiliary 12 VDC (ground)
G
P1-6 Auxiliary 12 VDC (positive)
AUXILIARY WIRING CIRCUITS, cont’d.
11 10 9
5 4 3
8 7 6
2 1
12
13
14
15
16
P1
B
C
A
G
H
D
E
F
E
NOR000799A
5
11 10 9
5 4 3
8 7 6
2 1
12
13
14
15
16
P1
G
F
A
B
D
E
C
NOR000800A