44
www.norcold.com
Polar Series N7V, N7X, N7XL / N8V, N8X, N8XL
TROUBLESHOOTING FLOWCHARTS - N7LX AND N8LX MODELS, cont’d.
Possible Cause:
The DC heater has failed (3-way mod-
els only).
Fault Code - “dc” “HE” with audible alarm
CODE
CODE
Alternately flashes “dc” and “HE”
with an audible alarm.
NOR000717A-1
Check DC heater resistance.
See figure, below.
NO
Replace DC heater.
YES
Replace DC board
assembly.
Resistance
0.81 to 0.91
Ohms?
Fault Code - “AC” “rE” with audible alarm
Possible Cause:
On the main control board assembly
(power board), the AC heater relay is
stuck closed. This fault can be displayed
in ANY MODE
NOR000708A
Replace main control board assembly
(power board).
On the main control board
assembly (power board), the
AC heater relay is stuck closed.
CODE
CODE
Alternately flashes “AC” and “rE”
with an audible alarm.
Possible Cause:
The contacts of DC heater relay (K1 on
the DC Board) are stuck closed. This
fault can be displayed in ANY MODE.
Fault Code - “dc” “rE” with audible alarm
NOR000721A
Replace DC board assembly.
DC heater relay stuck
closed.
CODE
CODE
Alternately flashes “dc” and “rE”