Specifications
MODEL
982 & 9182
983 & 9183
962 & 9162
963 & 9163
Storage Volume
cu. ft.
7.5
7.5
6.3
6.3
Cut-Out Dimensions
W x H x D
in.
23 1/2 x 59 7/8 x 24
23 1/2 x 59 7/8 x24
23 1/2 x 52 7/8 x 24
23 1/2 x 52 7/8 x 24
Certified Vent Kit
Refer to "Installation Requirements"
manual for details
Kit No. 3
Venting & Installation
Certified Installation Requires;
Vent Kit No. 3 installed without modification,
Unobstructed air flow across the refrigerator’s cooling system,
Clearances between the refrigerator and any adjacent surface
Top
0"- 1/4"
Sides
0"-1/2"
Rear
0"-1"
Bottom
0"
Door Panel Dimensions (Inches)
Upper Door H x W
Lower Door H x W
Thickness = 3/16"
14 17/32 x 21 19/32
38 5/8 x 21 19/32
14 17/32 x 21 19/32
38 5/8 x 21 19/32
14 17/32 x 21 19/32
31 5/8 x 21 19/32
14 17/32 x 21 19/32
31 5/8 x 21 19/32
Supply Voltage Requirements
DC
AC
15.4 Max.-10.5 Min.
132 Max.-108 Min.
15.4 Max.-11.5 Min.
132 Max.-108 Min.
15.4 Max.-10.5 Min.
132 Max.-108 Min.
15.4 Max.-11.5 Min.
132 Max.-108 Min.
Operating Requirements
LP Gas Operation
12 volt DC is required to operate and maintain the operating controls.
12 volts are needed to operate the interior light, moisture reduction heater, and the gas ignition
circuit. LP (Propane) Gas at supply pressure of 11" Water Column needed for LP GAS operation.
.0155 Orifice
.0155 Orifice
.015 Orifice
.015 Orifice
AC Operation
12 volt DC is required to operate and maintain the operating controls
120 volt, 60 Hertz grounded AC circuit is needed to operate the AC heater.
12 volts are needed to operate the interior light and the moisture reduction heater.
3