Ultium Motion Quick Start Guide                                                                                                        

 

(Rev A) 

4

 

Configuring the Hardware  

Before the Ultium Motion system can be used, the device software settings must be configured to recognize the different 
components that make up the system. Follow the instructions below to update the receiver firmware, sensor firmware, and 
sensor assignment to prepare for a data collection.  

 

Step 1 

 
Open the MR3 software and click on the Hardware Setup 
button in the upper right-hand corner. 

 

 

 

Step 2 

 
After connecting the Ultium Receiver to the USB port on 
the computer, select the Ultium icon, within the 

‘New 

Devices

 area, and click the Insert button. 

 
 

 

 

 

Step 3 

 
The Ultium hardware setup window will appear as 
shown. 
 

Within the “

General

” tab

, select the desired settings for 

the system, i.e., name, sample rate. 
 
Note: If available, firmware updates for the Receiver and 
Sensors will be indicated here.  
 
If using myoSYNC, click the Use Noraxon myoSYNC 
checkbox. 
 

Additional settings are available within the “Advanced” 

tab. 
 
Note: If multiple Ultium systems are in use, separate 
networks assignments are required for each Receiver. 
 

 

 

 

 

Summary of Contents for Ultium Motion

Page 1: ...Ultium Motion Quick Start Guide 1 Rev A Ultium Motion Quick Start Guide ...

Page 2: ...fer to the Ultium Motion User Manual P 8708 1 System Unboxing The Ultium Motion System is packed within a reinforced padded box for storage and protection during transport Upon arrival carefully remove all contents and verify the following components are present Figure 1 Ultium Receiver 880 Figure 2 Ultium Sensor Charger 873 Figure 3 Motion Sensor 870 or 876 Figure 4 Sensor Charger to Receiver Cab...

Page 3: ...870 into the Sensor Charger 873 Note Sensor power button LED must face the front of the Charger i e toward the charger LEDs Step 3 Connect the Receiver to the Sensor Charger 873 using the ports on either side of the Receiver Step 4 Insert the power supply PSU1 barrel connector into the associated receptacle on the back of the Ultium Receiver to charge sensors Note Sensor LED will show solid orange...

Page 4: ...software 1 Insert the MR3 USB flash drive into the PC 2 Open the installer application e g noraxon mr 3 18 00 and follow the instructions 3 After installation an icon will be created on the desktop 3 2 Companion Software Activation The companion software must be activated before unrestricted use is possible 1 Open MR3 2 A dialog box will indicate how many more times MR3 can be opened 3 Click Activ...

Page 5: ...upper right hand corner Step 2 After connecting the Ultium Receiver to the USB port on the computer select the Ultium icon within the New Devices area and click the Insert button Step 3 The Ultium hardware setup window will appear as shown Within the General tab select the desired settings for the system i e name sample rate Note If available firmware updates for the Receiver and Sensors will be i...

Page 6: ...of the Charger i e toward the Charger LEDs Step 5 After detection is complete click Replace to replace all existing sensor serial numbers associated with this device or Add to append additional sensor serial numbers to an already existing list Step 6 Assign sensors to body segments by clicking the dropdown and selecting the desired location from the pop up menu Note Segments already assigned to a ...

Page 7: ...ns Head Middle of the back of the head Upper Thoracic In line with the spinal column at C7 T1 but high enough to not be affected by upper trapezius muscle movement Lower Thoracic In line with the spinal column at L1 T12 Pelvic Body area of sacrum Upper Arm Midway between the shoulder and elbow joints lateral to the bone axis Forearm Posterior distal region where there is a low amount of muscle tis...

Page 8: ...sired body segment sensors and associated data to include in the measurement configuration Step 3 Continue to the next step by clicking Start Measure Activate the hardware by clicking Activate Note If operating within a distorted magnetic environment open the Motion Calibration dropdown menu on the right side toolbar to select a Functional Calibration then click Activate Step 4 In the right side t...

Page 9: ... Measure Again to return to the measurement screen or click Save View to visualize the recording 7 Viewing a Record To view a previously recorded record click the Database tab Records are organized by Project and Subject name Double click on the record of interest to open the record in the Viewer tab 8 Further Use Features of MR3 There are many additional features built within MR3 Such as Multi ac...

Reviews: