Noraxon Ultium EMG System Quick Start Manual Download Page 2

Insole Smart Lead Quick Start Guide                                                                                                                                           
 

(Rev A) 

Welcome from Noraxon 

Congratulations on acquiring your new Ultium Insole System! 
 

This guide will provide you with step by step instructions on how to install your new 
hardware and software, adjust device settings, and record your first data set.  
 
Let’s begin by walking through how to install your new hardware. 

 

Note: This is not meant to be a complete manual, but a guide to help you get started with your system. For 
more  detailed  instructions  on  operating  the  Ultium  system  and  its  features  please  refer  to  the  complete 

Ultium EMG User Manual

, also included with your system. 

 

1  System Unboxing 

The Ultium Insole system is packed within a reinforced padded box for storage and protection during 
transport. Upon arrival, carefully remove all contents and verify the following components are present. 

 

Contents will vary depending on the purchased package. 
 

 

 

 

Figure 1 - Ultium Receiver (part 

#880) 

Figure 2 - EMG Sensor Docking Station (part #883 

Figure 3 - EMG Sensor (part 
#810) 

 

 

 

Figure 4 - Ultium Insole Smart Lead 

(part # 826) 

Figure 5 - A to B USB Cable (part #CBL2) 

Figure 6 - EMG Sensor 

Charger Power Source (part 

#PSU1) 

 

 
Your system may differ depending on the number of sensors included with your 
shipment, quantities of EMG sensors, EMG SmartLeads Sensor Docking 
Stations, and Docking Station Cables.  
 
Additional items that may be included with your Ultium System include: 

 

 

Double side tape samples (part #842C) 

 

Sample electrodes (typically dual electrodes (part #272) 

 

Ultium User Manual (part #P-8808)  

 

Figure 8 

– Sensor Docking Station 

to Ultium Receiver cable (part# 

CBL34) 

Summary of Contents for Ultium EMG System

Page 1: ...Insole Smart Lead Quick Start Guide 1 Rev A Ultium Insole Quick Start Guide...

Page 2: ...orced padded box for storage and protection during transport Upon arrival carefully remove all contents and verify the following components are present Contents will vary depending on the purchased pa...

Page 3: ...ector on the rear of the Ultium Receiver 880 Insert the opposite end of the USB cable into an available USB port on the computer Step 2 Insert the EMG probes into the Sensor Docking Station 883 Step 3...

Page 4: ...ck Start Guide 4 Rev A Step 5 Connect the Insole SmartLead 826 to the Ultium Sensor 810 The Ultium Sensor will blink purple after the SmartLead is detected Step 6 Connect the Insole Sensor 826x to the...

Page 5: ...tallation file and follow the Wizard s instructions 4 After installation an icon will be created on the desktop 3 2 Companion Software Activation The installed companion software must be activated bef...

Page 6: ...e USB port of the computer via USB Cable CBL2 Step 3 The Ultium Settings dialog will appear as shown Within the Settings Tab select the desired collection Sampling Rate If using MyoSync check the Use...

Page 7: ...t Sensors in Charger to load all serial numbers into the MR3 software Step 6 After detection is complete click Yes to replace all existing sensor serial numbers associated with this device Step 7 Sele...

Page 8: ...d outline is an average of the sub zones Example Heel average of the Medial and Lateral heel zones 4 Zone Combined Each zone shown by the red outline is an average of the sub zones Example Heel averag...

Page 9: ...the Home screen click on the myoMUSCLE module icon Create a New Subject Select New Configuration Step 2 Insert the devices to be used for the measurement into the configuration by dragging a device i...

Page 10: ...step by selecting Measure Step 4 After checking for normal signal display you are ready to record a measurement Select Record at the top left of the screen and begin your protocol After completing yo...

Page 11: ...e to you through the system s you have purchased refer to the MyoResearch User Manual and the corresponding Hardware User Manual for this device If for any reason you find our support content to be in...

Page 12: ...n cleaning the insoles Clean with isopropyl alcohol or disinfectant wipes Dampen the surfaces and do not allow solution into the vent holes Each insole has 5 vent holes which must remain open and free...