7
Connecting the Sensors to the CANbus
1.
Route cable C03 from the input module to the 8-way coupler (E11).
2.
Connect both roll sensors to the 8-way coupler. Fasten the 8-way coupler to the boom
with cable ties.
3.
Connect the main lift sensor to the 8-way coupler using cable C04 and a 2-way coupler
(E12). Cable C04 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.
4.
Connect each 3-way coupler (E10) between two cables (C05). Insert a plug (P03) into the
unused connector on each 3-way coupler.
5.
Connect two cables (C05) to the 8-way coupler and route along the booms to the wing
sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.
Figure 20: UC5 Module Locations and Cable Connections
6.
At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.
The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the
CANbus cable into the 2-way coupler.
7.
Insert the plugs (P03) into the unused connectors on E11.
Summary of Contents for UC5 Rogator 600