34
6.3.5
Turning Booms OFF or ON
You can turn UC4+ automatic height control off for each individual boom
section. In
AUTO
mode, boom sections that are turned off will not
automatically adjust, and are indicated with a "
D
" in the Normal Operating
Screen, as shown below.
Table 9 – Turning Left Boom OFF
D 8
8 A
Left boom is turned OFF ("
D
" = disabled) control, the current
average boom height = 88 Right boom is in
AUTOMATIC
mode.
Sections can be turned off or on in the
SETUP
menu. Refer to the menu
structure shown in
Table 5
. Locate the menu prompts named below.
1.
Ensure the UC4+ control panel is in
MANUAL
mode, at the
Normal Operating Screen.
2.
Navigate to the "
More ?
" menu prompt in the
SETUP
menu.
Toggle the "
AUTO (YES)
" switch to confirm.
3.
Navigate to the boom section you wish to turn off or on, for
example "
Right ?
". Toggle the "
AUTO (YES)
" switch to
confirm.
4.
At the "
Right On
" menu prompt toggle the "
+/-
" switch to
change the status.
5.
Toggle and hold the "
SETUP
" switch for two seconds to return
to the Normal Operational Screen.
6.3.6
Remote Switches
Remote control of the
AUTO
and
MANUAL
modes may be wired to the
control panel. This feature allows the operator to control the mode of the
UC4+ Spray Height Control system from an external switch or controller.
Contact NORAC for further information concerning wiring and enabling
Remote Switch control.