27
6.3 M
ANUAL
S
YSTEM
S
ETUP
The UC4+ control panel will not permit
AUTO
mode unless the system has
been completely configured by either the Automatic System Setup or
Manual System Setup. Manual Setup will require setting up each sensor
(programming serial numbers and sensor locations) as well as tuning the
hydraulic parameters manually.
6.3.1
Setting Up Sensors
Table 4 – Left Channel SENSOR DISPLAY Menus
Navigating past the end of the menu will return the panel to the Sensor…”More” Menu
LI off
Informs you that no left inside (
LI
) sensor is installed; or else shows the
information as described for
LO
.
LOht 115
Informs you that the current height reading of the
LO
sensor is 115 cm
(45 inches).
LO 1240
Informs you that serial number 1240 is installed as the left outer (
LO
)
sensor.
Navigating past the end of the menu will return the panel to the Sensor…”More” Menu
Sensor information (serial numbers, locations) can be entered in the
SENSOR DISPLAY
menu manually. You need to know the serial number
of the sensor you wish to enter and the physical location. The serial number
is stamped on the sensor housing opposite the cable.
The left channel menu prompts are described in
Table 4
. For the other
channels, the basic structure and behavior of the prompts is the same.
Entering Sensor Serial Numbers
To enter a sensor serial number in one of the boom locations:
1.
Ensure the UC4+ control panel is in
MANUAL
mode, at the
Normal Operating Screen.
2.
Navigate to the "
More ?
" menu prompt in the
SENSOR
DISPLAY
menu. Toggle "
AUTO (YES)
" to confirm.
3.
Navigate to the boom section you put the sensor on, for example,
"
Right ?
", if the sensor is mounted on the right hand boom.
Toggle "
AUTO (YES)
" switch.
4.
Navigate to the boom location you mounted the sensor on, for
example, "
LO
" for the left outer sensor. This screen will show
the previously installed sensor serial number (if any) as shown in
Table 4
.
5.
Toggle the "
+
" switch once to search for the all connected
sensors.