HYDRAULIC INSTALLATION
WARNING!
The hydraulic system creates very high
pressure. Before disconnecting any
hydraulic lines ensure all pressure has
been bled from the system.
IMPORTANT:
Component
failure
due
to
oil
contamination is not covered under the
UC4+ Spray Height Control system
warranty. It is recommended that a
qualified technician does the hydraulic
installation.
Sprayers with a model year of
2007 and older require the main lift valve
to be changed. See Section 4 for
instructions on how to do this.
1.
Use
Figure 1
as a reference for
installing the hydraulics.
2.
On a clean surface remove all plastic
plugs from the NORAC expansion valve
block (
V01
).
3.
Install the 6MB 6MOR fitting (
F04
) into
the A and B ports of the expansion block
(
Figure 2
).
Figure 2 - Third station expansion block
assembly
4.
Remove the three 4MBP plugs from the
UC4+ 2 station valve block.
5.
Coat the three o-rings in hydraulic oil
and install them into the expansion
block.
Make sure the o-rings are properly
seated.
Figure 3 - Expansion Valve O-Ring
Placement
6.
Thread the 4.5” studs into the UC4+
block.
Figure 4 - Expansion Valve Stud
Insertion