11
When installing the UC4+ sensors
(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 9).
5.
Sensor cables should run through the
mounting bracket tube and then behind
the member the bracket is mounted onto.
Cable-tie the connector in place. The
cable must not be allowed to hang below
the boom (
Figure 6
).
Figure 6 – Another Acceptable Mounting
Avoid
mounting
sensors
in
locations where they may read
from parts of the boom as shown
in Figure 7.
Figure 7 – Poor Mounting
(Sensor Reading off Boom)
General mounting rules for UC4+
ultrasonic wing sensors:
a)
In its lowest position, the sensor mouth
must be 9 inches or more from the
ground.
b)
The bottom of the sensor must be at least
9 inches in front of the spray nozzles.
c)
The bottom of the sensor must be at least
9 inches above the spray nozzles.
d)
Ensure that there are no obstructions
within
a
12-inch
diameter
circle
projected directly below the center of the
sensor.
e)
The sensor should be approximately
vertical at normal operating heights.
Figure 8 – Sensor Mounting Guidlines
A
B
B
D
C
Ultrasonic
Acoustic Cone
Summary of Contents for FLEXI-COIL 67 Series
Page 10: ...7 Figure 3 Hydraulic Plumbing Schematic ...
Page 15: ...12 Figure 9 Sensor Serial Number Installation Location 3 SENSOR SYSTEM 5 SENSOR SYSTEM ...
Page 30: ...5 3 ITEM C02 44668 SENSOR BRANCH CABLE 5 4 ITEM C02B 44664 CABLE UC4 CAN NODE DUAL ...
Page 31: ...5 5 ITEM C03 44656D CABLE VALVE VARIABLE RATE DT 5 6 ITEM C04 44651 VALVE EXTENSION CABLE ...
Page 32: ...5 7 ITEM C10 44650 09 POWER CABLE FOR FLEXI COIL 67 SERIES ...