BEFORE USING THE STEAM GENERATOR, READ AND FOLLOW THIS INSTRUCTION MANUAL. 
PLEASE READ THE SAFETY INSTRUCTIONS ON THIS HANDBOOK BEFORE PROCEEDING  
WITH THE FIRST USE.

    Attention!! Use only distilled water
    Attention!! Hot surface
    Attention!! Steam... burning danger

SAFETY REGULATIONS  

The electric supply connection shall be made by a qualified electrician 
and comply with IEC 60364-1.
It is recommended that the electric supply to this machine should include 
either a residual current device that will interrupt the supply if the leakage 
current to earth exceeds 30ma for 30ms or a device which will prove 
the earth circuit and the outlet used should be grounded. Do not use 
extension cords.

SAFETY VALVE

 This machine is equipped with two safety valves, able 

to ensure the safety of the machine itself in case other primary control 
devices are inefficient (due to a failure). Due to the extreme importance  
of these components and as not to compromise the safety of the machine, 
it is recommended to provide to check them and to substitute them 
through an authorized service center every 2 years starting from the 
purchasing date. For parts & service, please contact nora technical 
dept. 1-800-336-5096.

PRESSURE SWITCH

 This machine is equipped with a pressure switch 

able to check and to maintain the pressure under certain preset limits (ref. 
“rated pressure” on the technical label underneath the machine). In case 
there would be a steam leakage on the lower side of the machine, it 
means that the functioning of this device has been compromised and the 
safety valve has been involved as to limit the boiler’s internal pressure.  

It is recommended not to use the ma chine, immedia tely unplug 

the machine from the power feeding and call the service center.
MUD DRAIN FROM THE BOILER

 The machine is equipped with a 

warning system “mud drain”. The writing CALC will appear on the display 
to indicate that it is necessary to proceed with the boiler cleaning.  
The opening of the drain cap has to be strictly carried out when the 
machine has been switched off (plug not inserted) for at least 5 hours. 
See Maintenance of steam cleaner in this guide. 

ATTENTION.

 Do not use the appliance within the range of persons 

unless they wear protective clothing.

ATTENTION.

 The high pressure jets can be dangerous if not used  

properly. The jet does not have to be directed against persons, elec-
trical devices under tension or the unit itself.
Do not direct the jet against yourself or others in order to clean clothes 
or footwear. Disconnect power before effectuating maintenance on 
user’s responsibility. This machine is not intended for use by persons 
(including children) with reduced physical, sensory or mental capabili-
ties, or lack of experience and knowledge. Monitor the children so  
they cannot play with the machine. To ensure the machine’s safety, use 
only original spare parts from the manufacturer or spare parts approved 
by the manufacturer. For parts & service, please contact nora technical 
dept. 1-800-336-5096.

ATTENTION.

 Pressure hoses, fitting and couplings are important for the 

safety of the machine. Use only those recommended by the manufacturer.
Do not use the machine if the power cord or other important parts of  
the machine are damaged, i.e. safety devices, pressure hoses and trig-
ger gun. The hand-arm vibration data, referred to this device, are not 
mentioned as they are below 2.5 m / s ².

Technical data - Generator

EU: nora pro steamer

 Version 230 V

US: nora pro steamer

 Version 120 V

Steam boiler

AISI 304 stainless steel (with heating element which can be replaced)

Chassis

Upper and lower housing: P04 steel

Steam boiler volume

I

1,5

Water tank

I

3

Working pressure

bar/kPa

8

800

Permissible Steam Pressure

bar/kPa

12

1200

Max.

 

Steam production

Kg/h

3,8

2,64

Max.

 

Steam T

o

o

C/ 

o

F

174 

o

C

345 

o

F

Kickback forces

N

< 20

Voltage

V-Hz

230 – 50/60

120 – 50/60

Maximum output

kW

2,45

1,65

Steam boiler output

kW

2,4

1,6

Power cable

m/feet

5

16,4

Mass

kg/lb

15

33

06/2016

1/2